LiftMaster J J -New style with thermal overload Manual - Page 8

Entrapment protection accessories, ADJUSTMENT, Limit switch adjustment, OPTIONAL

Page 8 highlights

I N S TA L L AT I O N ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL) WARNING SENSING EDGES & PHOTO EYES To reduce the risk of SEVERE INJURY or DEATH, ALWAYS install Sensing devices provided for door industry type operators with an isolated normally open (N.O.) output are compatible with your operator. This includes pneumatic and electric edges, and through CAUTION reversing sensors when the 3-button control station is out of sight of door or ANY other control (automatic or manual) is used. Reversing devices are recommended for ALL installations. beam and retro reflective photo eyes. If your door does not have a bottom sensing edge or safety photo eyes and you wish to add a safety device to your application, please contact your local LiftMaster Authorized Dealer. If not pre-installed by the door manufacturer, mount the sensing edge on the door according to the instructions provided with the WIRING For wiring of your sensing device to the operator, refer to the wiring diagrams provided with your operator. See field connection terminals identified as a Sensing Device or Safety Edge. edge. The sensing edge may be electrically connected by either coiled cord or take-up reel. Refer to the steps below. Important Notes: a. Proceed with Limit Switch Adjustments described below before TAKE-UP REEL Take-up reel should be installed 12" (30.48 cm) above the top of the door. making any sensing edge wiring connections to operator as described below. COIL CORD AVERTISSEMENT b. Electrician must hardwire the junction box to the operator electrical box in accordance with local codes. Connect operator end of coil cord to junction box (not provided) fastened to the wall approximately halfway up the door opening. WARNING ATWTAENRTNIIONNG A D J U S T M E N T LIMITCSAWIUTCTHIAODJNUSTMENT NOTE: Make sure the limit nuts are positioned between the limit switches before proceeding with adjustments. 1. Depress retaining plate to allow nut to spin freely. After adjustment, release plate and move nut back and forth to ensure it is fully seated in slot. 2. To increase door travel, spin nut away from limit switch. To decrease door travel, spin limit nut toward limit switch. 3. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening. 4. Repeat steps 1 and 2 for close cycle. Adjust close limit nut so that the limit switch is engaged as door fully seats at the floor. WARNING To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect electric power BEFORE manually moving limit nuts. AVERTISSEMENT Open Limit Switch ATTENTION AAVDERVETIRSTSEENMCEIANT PARVEECRATUISCSIÓECMNloseELimNit STwitch Actuator Retaining Plate Auxiliary Open Limit Switch 8 Safety (Aux. Close) Limit Switch

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

8
ENTRAPMENT PROTECTION ACCESSORIES
(OPTIONAL)
SENSING EDGES & PHOTO EYES
Sensing devices provided for door industry type operators with an
isolated normally open (N.O.) output are compatible with your
operator. This includes pneumatic and electric edges, and through
beam and retro reflective photo eyes. If your door does not have a
bottom sensing edge or safety photo eyes and you wish to add a
safety device to your application, please contact your local
LiftMaster Authorized Dealer.
If not pre-installed by the door manufacturer, mount the sensing
edge on the door according to the instructions provided with the
edge. The sensing edge may be electrically connected by either
coiled cord or take-up reel. Refer to the steps below.
Important Notes:
a. Proceed with Limit Switch Adjustments described below before
making any sensing edge wiring connections to operator as
described below.
b. Electrician must hardwire the junction box to the operator
electrical box in accordance with local codes.
WIRING
For wiring of your sensing device to the operator, refer to the
wiring diagrams provided with your operator. See field connection
terminals identified as a Sensing Device or Safety Edge.
TAKE-UP REEL
Take-up reel should be installed 12" (30.48 cm) above the top of
the door.
COIL CORD
Connect operator end of coil cord to junction box (not provided)
fastened to the wall approximately halfway up the door opening.
ADJUSTMENT
To avoid SERIOUS PERSONAL INJURY or DEATH from
electrocution, disconnect electric power BEFORE manually
moving limit nuts.
WARNING
WARNING
INSTALLATION
To reduce the risk of SEVERE INJURY or DEATH, ALWAYS install
reversing sensors when the 3-button control station is out of
sight of door or ANY other control (automatic or manual) is
used. Reversing devices are recommended for ALL installations.
WARNING
WARNING
Open Limit Switch
Retaining Plate
Auxiliary Open Limit Switch
Close Limit Switch
Actuator
Safety (Aux. Close) Limit Switch
LIMIT SWITCH ADJUSTMENT
NOTE:
Make sure the limit nuts are positioned between the limit
switches before proceeding with adjustments.
1.
Depress retaining plate to allow nut to spin freely. After
adjustment, release plate and move nut back and forth to
ensure it is fully seated in slot.
2. To
increase
door travel, spin nut
away
from limit switch. To
decrease
door travel, spin limit nut
toward
limit switch.
3.
Adjust open limit nut so that door will stop in open position
with the bottom of the door even with top of door opening.
4.
Repeat steps 1 and 2 for close cycle. Adjust close limit nut so
that the limit switch is engaged as door fully seats at the floor.