LiftMaster LA400UL Installation Manual - Page 7
Operator Specifications, External Entrapment Protection Device Inputs non
View all LiftMaster LA400UL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
INTRODUCTION Operator Specifications Usage Classification Main AC Supply System Operating Voltage Accessory Power Solar Power Max Maximum Gate Weight/Length 90 Degree Travel Time* Maximum Travel Range* Maximum Daily Cycle Rate Maximum Duty Cycle Operating Temperature Expansion Board External Entrapment Protection Device Inputs (noncontact and/or contact) Class I, II, & III 120 Vac, .5 Amps (6.5 Amps including Accessory Outlets) 24 Vdc Battery Run / Direct Plug-in Transformer Charge 24 Vdc, 500mA max. for ON + SW (switched) 24 Vdc at 60 watts max. 850 lbs. (385.6 kg) / 10 ft (3.0 m) 750 lbs. (340.2 kg) / 12 ft (3.7 m) 650 lbs. (294.8 kg) / 14 ft (4.3 m) 550 lbs. (249.5 kg) / 16 ft (4.9 m) 15-18 seconds 115 degrees 100 cycles / day 4 min on -20°C to 60°C (-4°F to 140°F) Optional Main board - up to 2 close entrapment protection devices and 1 open entrapment protection device. Expansion board - up to 3 entrapment protection devices configurable to either close or open direction and up to 4 edge sensors using wireless edge sensor kit model LMWEKITU. *Travel time and range are affected by A and B mounting dimensions, see INSTALLATION. 7