LiftMaster MEGA SWING MEGA SWING - MSWDCBB Manual - Page 16

Maintenance, Battery Maintenance / Testing, Battery Handling / Storage, General Service

Page 16 highlights

MAINTENANCE Check at the intervals listed in the following chart: ITEM Instant Reverse Device (IRD) Fasteners Bearings & Shafts PROCEDURE Test IRD Reversal Check and tighten as required. Check for wear and lubricate. EVERY MONTH z EVERY 3 MONTHS EVERY 6 MONTHS z z Battery Maintenance Replace batteries. ◆  Repeat ALL procedures. EVERY 12 MONTHS EVERY 24 MONTHS ◆ ◆ z GENERAL SERVICE WARNING • Belt loose or needs replacement, adjust with 4 bolts that support motor to allow 1/4" play. CAUTION • Charge voltage for batteries should be 27.5 +0.05, -0 Vdc with batteries disconnected (Set with R63, shown on the Control Board Layout page). • Replace batteries with LiftMaster P/N MBAT batteries. Replace in pairs. WARNING To prevent possible SERIOUS INJURY or DEATH from WARNING electrocution or fire, BEFORE proceeding: • Disconnect ac power at the fuse box. • Disconnect dc power at the battery connection. BATTERY DISPOSAL Replaced batteries must be treated as a hazardous waste and disposed of in accordance with State, Local and Federal Regulations. See the battery manufacturer's Material Safety Data Sheets (01-30839 "MSDS Sheets, Battery, Standard"). BATTERY REPLACEMENT AVERTISSEMENT Service Kits are available for battery replacement. Please contact Technical Support (see back of this document for contact information). ATTENTION BATTERY MAINTENANCE / TESTING The batteries are maintenance free. However, to insure proper and safe operation, it is recommended that the batteries be replaced every two years. Battery testing is conducted automatically. See the Battery Test Description section for manually initiating the battery test. AVERTISSEMENT BATTERY HANDLING / STORAGE Refer to the battery manufacturer's Material Safety Data Sheets (01-30839 "MSDS Sheets, Battery, Standard"). LiftMaster does not recommend storage of batteries in the field. Batteries are intended for immedAiateVusEe. RTISSEMENT ADVERTENCIA PRECAUCIÓN ADVERTENCIA 16 ADVERTENCIA

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

EVERY
EVERY
EVERY
EVERY
EVERY
ITEM
PROCEDURE
MONTH
3 MONTHS
6 MONTHS
12 MONTHS
24 MONTHS
Instant Reverse Device
Test IRD Reversal
z
(IRD)
Fasteners
Check and tighten
as required.
z
Bearings & Shafts
Check for wear
and lubricate.
z
Battery Maintenance
Replace batteries.
z
16
MAINTENANCE
Check at the intervals listed in the following chart:
±
Repeat ALL procedures.
BATTERY MAINTENANCE / TESTING
The batteries are maintenance free. However, to insure proper and
safe operation, it is recommended that the batteries be replaced
every two years. Battery testing is conducted automatically. See
the Battery Test Description section for manually initiating the
battery test.
BATTERY HANDLING / STORAGE
Refer to the battery manufacturer’s Material Safety Data Sheets
(01-30839 “MSDS Sheets, Battery, Standard”). LiftMaster does
not recommend storage of batteries in the field. Batteries are
intended for immediate use.
GENERAL SERVICE
Belt loose or needs replacement, adjust with 4 bolts that
support motor to allow 1/4" play.
Charge voltage for batteries should be 27.5 +0.05, -0 Vdc
with batteries disconnected (Set with R63, shown on the
Control Board Layout page).
Replace batteries with LiftMaster P/N MBAT batteries. Replace
in pairs.
BATTERY DISPOSAL
Replaced batteries must be treated as a hazardous waste and
disposed of in accordance with State, Local and Federal
Regulations. See the battery manufacturer’s Material Safety Data
Sheets (01-30839 “MSDS Sheets, Battery, Standard”).
BATTERY REPLACEMENT
Service Kits are available for battery replacement. Please contact
Technical Support (see back of this document for contact
information).
To prevent possible SERIOUS INJURY or DEATH from
electrocution or fire, BEFORE proceeding:
• Disconnect ac power at the fuse box.
• Disconnect dc power at the battery connection.
WARNING
WARNING