LiftMaster RSW12UL Installation Manual - Page 7
Operator Specifications, External Entrapment Protection Device Inputs non-contact
View all LiftMaster RSW12UL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
INTRODUCTION Operator Specifications Usage Classification Class I & II Main AC Supply 120 Vac, .5 Amps (6.5 Amps including Accessory Outlets) System Operating Voltage 12 Vdc Battery Run / Battery Backup Accessory Power 12 Vdc, 500mA max. for ON + SW (switched) Solar Power Max 12 Vdc at 30 watts max. Maximum Gate Weight/Length 400 lbs. (181.4 kg)/16 ft. (4.9 m) 600 lbs. (272.2 kg)/12 ft. (3.7 m) 700 lbs. (317.5 kg)/10 ft. (3 m) 800 lbs. (362.9 kg)/8 ft. (2.4 m) 1000 lbs. (543.5 kg)/6 ft. (1.8 m) 90 Degree Travel Time* < 17 seconds Maximum Travel Range* 115 degrees Maximum Daily Cycle Rate 250 cycles/day Maximum Duty Cycle Continuous Operating Temperature Without Heater: -20°C to 60°C (-4°F to 140°F) With Optional Heater: -40°C to 60°C (-40°F to 140°F) Expansion Board Optional External Entrapment Protection Device Inputs (non-contact Main board - up to 2 close entrapment protection devices and 1 open entrapment and/or contact) protection device. Expansion board - up to 3 entrapment protection devices configurable to either close or open and up to 4 edge sensors using wireless edge sensor kit model LMWEKITU . *Travel time and range are affected by A and B mounting dimensions, see INSTALLATION. 7