LiftMaster SL3000UL3 Owners Manual - Page 22

DC2000 Device Wiring - owner manual

Page 22 highlights

DC2000™ DEVICE WIRING Manually Operated DC2000™ Devices Manual external devices should be dry-contact which do not consume any current like push buttons or a key switch. Key switch is for property owner's emergency access ONLY. DO NOT FOR USE FOR A EMERGENCY FIRE/POLICE KEY ACCESS. Contact your local Fire/Police municipalities for more information on correct Fire/Police emergency key access. Manual One-Button 1234567 See Accessories 1234567 Reset button and interlock wires, Do Not Remove. Push and HOLD button to Open. Push button again and HOLD to Close. 1234567 Manual Key Switch See Accessories Turn and HOLD key to Open. Turn key again and HOLD to Close. Manual 3-Button N.O. 3 N.O. 2 N.O. 1 Com 4 4 Com Com 4 Push and HOLD a button to operate. DC2000™ Entrapment Protection Devices It is recommended using separate entrapment protection devices to maintain gate safety when the DC2000™ is needed for any reason. The entrapment protection devices connected to the OmniControl™ board and surge suppressor WILL NOT protect the gate when there is a AC power failure and the DC2000™ is used. See Accessories 3 Edge Sensor CENTER SAFETY EXIT SENSOR ALARM SENSOR ALARM W4 G B A MS LINK CENTER SAFETY EXIT DC-BACKUP DC-BACKUP ALARM SENSOR SYSTEM ON SENSORS 1 3 1 3 REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT 1 3 ON OPEN RIGHT COMMAND PROCESSED FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA POWER OVERLOAD OmniControl™ Board Sensor Connection +12Vdc 12Vdc Failsafe Photoelectric Sensor 1234567 Ground Failsafe Photoelectric Sensor: If a photoelectric sensor is not working, loses power or photoelectric sensor is blocked, then the photoelectric sensor will stop all gate operation. 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

1
3
2
4
7
6
5
1
3
2
7
6
5
4
1
3
2
7
6
5
4
4
4
4
3
2
1
1
3
2
7
6
5
4
CENTER
SAFETY
EXIT
CENTER SAFETY
EXIT
FIRE
DEPT.
STRIKE
OPEN
RADIO
RECEIVER
TIMER
SYSTEM ON
EXIT
LOOP
ALARM
SENSOR
REVERSE
SENSOR
OPEN
STOP
CLOSE
SAFETY
LOOP
CENTER
LOOP
GATE
LOCKED
60
POWER
OVERLOAD
OFF
W4
OPEN LEFT
DC-BACKUP
ALARM
SENSOR
OPEN RIGHT
3
SENSORS
RESET
MOTOR
COMMAND
PROCESSED
ON
G B
MS LINK
A
MADE IN USA
POWER
OVERLOAD
DC-BACKUP
ALARM
SENSOR
SENSOR
20
DC2000™ DEVICE WIRING
Manually Operated DC2000™ Devices
Manual external devices should be dry-contact which do not consume any current like push buttons or a key switch.
Key switch is for property owner’s emergency access ONLY.
DO NOT FOR USE FOR A EMERGENCY FIRE/POLICE KEY ACCESS.
Contact your local Fire/Police municipalities for more information on correct Fire/Police emergency key access.
DC2000™ Entrapment Protection Devices
It is recommended using separate entrapment protection devices to maintain gate safety when the DC2000™ is needed for any reason.
The entrapment protection devices connected to the OmniControl™ board and surge suppressor
WILL NOT
protect the gate when there
is a AC power failure and the DC2000™ is used.
See Accessories
Com
N.O.
N.O.
N.O.
Com
Ground
+12Vdc
Com
See Accessories
Push and
HOLD
button to
Open.
Push button
again
and
HOLD
to
Close.
OmniControl™ Board
Sensor Connection
Failsafe Photoelectric Sensor:
If a photoelectric sensor is not working,
loses power or photoelectric sensor is blocked, then the photoelectric
sensor will stop
all
gate operation.
Push and
HOLD
a button to operate.
Turn and
HOLD
key to
Open.
Turn key
again
and
HOLD
to
Close.
Manual One-Button
3 Edge Sensor
12Vdc Failsafe
Photoelectric
Sensor
Manual 3-Button
Manual Key Switch
See Accessories
Reset button and
interlock wires,
Do Not Remove.