LiftMaster SL585UL Installation Manual - Page 27

Reversal Force Dial, Test Buttons, Status LEDs, Settings 1-3, INPUT POWER, TIMER, GATE MOVING

Page 27 highlights

CONTROL BOARD OVERVIEW Reversal Force Dial The REVERSAL FORCE dial adjusts the force. See the Adjustment section. Settings 1-3: Fixed force settings (the force will not adjust due to gate wear or temperature changes) Settings 4-10: Automatically increase the force due to gate wear or temperature changes Test Buttons Used to operate the gate (OPEN, STOP and CLOSE). Also used to view the code history (refer to the Troubleshooting section). Status LEDs LED INPUT POWER TIMER GATE MOVING ACC PWR OVLD STATE OFF ON OFF ON 1 blink/second 2 blinks/second 8 blinks/second OFF ON 1 blink/second 8 blinks/second OFF ON DEFINITION OFF state AC power available The timer is disabled The timer is enabled The timer is running The timer is paused The timer is cancelled The gate is stopped The gate is opening or closing E1 (single entrapment) E2 (double entrapment) Accessory power is okay Accessory overload protector opened 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

27
Reversal Force Dial
The REVERSAL FORCE dial adjusts the force. See the
Adjustment
section.
Settings 1-3:
Fixed force settings (the force will not adjust due to gate wear or temperature
changes)
Settings 4-10:
Automatically increase the force due to gate wear or temperature changes
Test Buttons
Used to operate the gate (OPEN, STOP and CLOSE). Also used to view the code history (refer to the Troubleshooting section).
Status LEDs
LED
STATE
DEFINITION
INPUT POWER
OFF
OFF state
ON
AC power available
TIMER
OFF
The timer is disabled
ON
The timer is enabled
1 blink/second
The timer is running
2 blinks/second
The timer is paused
8 blinks/second
The timer is cancelled
GATE MOVING
OFF
The gate is stopped
ON
The gate is opening or closing
1 blink/second
E1 (single entrapment)
8 blinks/second
E2 (double entrapment)
ACC PWR OVLD
OFF
Accessory power is okay
ON
Accessory overload protector opened
CONTROL BOARD OVERVIEW