Linksys WVC80N User Guide - Page 39
Wireless Commands, Wireless status query - motion
UPC - 745883588428
View all Linksys WVC80N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Appendix D CGI Commands Parameter md_name1 ... md_name4 md_window1 ... md_window4 md_threshold1 ... md_threshold4 Return: Value and description Name of the motion detection area 1 ~ 4 (12 ASCII characters) The coordinates of motion detection window N (relative to resolution 640x480) X1, Y1, X2, Y2 The threshold of motion detection window N (0 - 255) HTTP/1.0 200 OK \r\n ... content-type: text/plain\r\n \r\n OK\r\n Notes: The first motion window is used for full screen. •• Use "md_switch1" as the switch for "full screen" or "sub-windows". •• The md_window1 is always set to 640x480 resolution. If "md_switch1=1", then the Camera will detect the entire video screen. With this setting, the remaining windows (sub-window 1~3) cannot be configured. If "md_switch1=0", then the Camera will detect the "md_window2~4" areas. Wireless Commands Wireless status query Method: GET URL: http:///adm/wireless_status.cgi Return: The Camera returns a Web page that contains the following messages: HTTP/1.0 200 OK \r\n ... content-type: text/plain\r\n \r\n signal_strength=100\r\n \r\n # Wireless signal, RSSI, Integer type, the value can be 1~100, 100 is the strongest. Wireless-N Internet Home Monitoring Camera 38