Magic Chef MCSCTG24S User Guide - Page 12

Gas Conversion

Page 12 highlights

gas conversion WARNING: Explosion Hazard • Use a new CSA International approved gas supply line. • Install a shut-off valve. • Securely tighten all gas connections. • If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36cm) water column. • Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. • Failure to do so can result in death, explosion, or fire. The range can be used with Natural Gas or LP/Propane Gas. The range is manufactured from the factory for use with Natural Gas. A kit for converting to LP/Propane Gas is supplied with your cooktop. The kit is marked "For LP/ Propane Gas Conversion". NOTE: When the cooktop is converted for LP/Propane Gas, the LP gas supply is required to provide a minimum of 10" to a maximum of 14" water column to the cooktop regulator. The conversion must be performed by a qualified service technician in accordance with the kit instructions and all local codes/requirements. CAUTION: Failure to follow instructions could result in serious injury. Parts Required Figure 12 Wrench 7mm Nut Driver Small Flat-Head Screwdriver (2 to 2.4 mm or 3/32" tip size, 60 mm long) Safety Glasses Converting to LP/Propane Gas Burner Type Max Output Kw Auxiliary Burner 1 Semi-Rapid Burner 2 Triple Ring Burner 4.5 Min Output Kw 0.3 0.55 1.5 Natural Gas Nozzle (mm) Cons (M3/h) 1 x 1.10 0.1 1 x 1.20 0.19 5 x ø0.99 0.43 LPG Nozzle Cons (mm) (g/h) 1 x 0.70 73 1 x 0.80 124 5 x ø0.56 327 1. Turn the manual shut-off valve to the closed position. (Refer to Figure 13.) 2. Unplug range or disconnect power. 3. Unscrew the regulator cap with the wrench. (Refer to Figure 14.) Figure 13 Manual Shut-Off Valve "Closed" Position Gas Supply Line To Range Regulator Figure 14 Retainer Pin Retulator Cap 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

12
GAS CONVERSION
WARNING
: Explosion Hazard
Use a new CSA International approved gas supply line�
Install a shut-off valve�
Securely tighten all gas connections�
If connected to LP, have a qualified person make sure gas pressure does not exceed 14” (36cm) water column�
Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and
authorized service personnel�
Failure to do so can result in death, explosion, or fire�
The range can be used with Natural Gas or LP/Propane Gas� The range is manufactured from the factory for use
with Natural Gas� A kit for converting to LP/Propane Gas is supplied with your cooktop� The kit is marked “For LP/
Propane Gas Conversion”�
NOTE
: When the cooktop is converted for LP/Propane Gas, the LP gas supply is required to provide a minimum
of 10” to a maximum of 14” water column to the cooktop regulator�
The conversion must be performed by a qualified service technician in accordance with the kit instructions and
all local codes/requirements�
CAUTION
: Failure to follow instructions could result in serious injury�
Parts Required
Figure 12
7mm Nut Driver
Small Flat-Head Screwdriver
(2 to 2�4 mm or 3/32” tip
size, 60 mm long)
Wrench
Safety Glasses
Converting to LP/Propane Gas
Burner Type
Max Output
Min Output
Natural Gas
LPG
Kw
Kw
Nozzle
(mm)
Cons
(M
3
/h)
Nozzle
(mm)
Cons
(g/h)
Auxiliary Burner
1
0�3
1 x 1�10
0�1
1 x 0�70
73
Semi-Rapid Burner
2
0�55
1 x 1�20
0�19
1 x 0�80
124
Triple Ring Burner
4�5
1�5
5 x ø0�99
0�43
5 x ø0�56
327
Figure 13
Figure 14
Manual Shut-Off Valve
“Closed” Position
To Range
Gas Supply Line
1�
Turn the manual
shut-off valve to
the closed position�
(Refer to Figure 13�)
2�
Unplug range or
disconnect power�
3�
Unscrew the regulator
cap with the wrench�
(Refer to Figure 14�)
Retainer Pin
Regulator
Retulator Cap