Maintenance routine 1. Drain water from the air tank, any moisture separators or air filter regulators. 2. Check for any unusual noise and/or vibration. 3. Pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced. WARNING: Never pull the ring of the safety valve when the tank is under pressure. WARNING: Risk of Bursting Check the safety valve. If safety valve does not operate properly over pressurization of the air tank may result in rupture or explosion causing personal injury and property damage. 4. Inspect air filter, replace if necessary. 5. Inspect air lines and fittings for leaks and correct as necessary. Each year of operation or if a problem is suspected, check condition of check valve. Replace if damaged or worn out. 6. Keep all screws, bolts, and covers tightly mounted. Check their conditions periodically. WARNING: Keep all screws, bolts and covers properly tightened. If screws plates or covers become loose personal injury or property damage may occur. Recommended interval of inspection and maintenance Inspect and maintain the compressor within the period as described in the following table. Part Action Overall Air lines and fittings Inspect for unusual noise and vibration Clean off dirt and dust with dry air. Inspect for leakage Daily (before/after use) - Weekly - - Monthly - Quarterly - Air tank Exhaust all air and drain condensation in the air tank. (open the drain valve.) - - - Inspect for scratches, dents, or leakage. - - - Inspect rust, pin - - - holes, or other imperfections that could cause it to become unsafe. Bolts and nuts Inspect for - tightness. - - Handle Wipe off oil and - grease. - - Safety valve Check function - - - Cut-out pressure Check and adjust. - - - Air filter Clean or replace if - - - necessary. Lubrication Storage This air compressor is equipped with an Oil-Less pump designed for durability and no maintenance. Before you store the air compressor, make sure you do the following: • Review the "MAINTENANCE" and "OPEATION" sections and perform maintenance as necessary. Be sure to drain water from the air tank. • Protect the air hose from damage (such as being stepped on or run over). Store the air compressor in a clean and dry location. 12 ENGLISH

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

12
ENGLISH
Maintenance routine
1.
Drain water from the air tank, any moisture sepa-
rators or air filter regulators.
2.
Check for any unusual noise and/or vibration.
3.
Pull the ring on the safety valve to make sure that
the safety valve operates freely.
If the valve is stuck or does not operate smoothly, it
must be replaced.
WARNING:
Never pull the ring of the safety
valve when the tank is under pressure.
WARNING:
Risk of Bursting
Check the safety valve. If safety valve does not
operate properly over pressurization of the air
tank may result in rupture or explosion causing
personal injury and property damage.
4.
Inspect air filter, replace if necessary.
5.
Inspect air lines and fittings for leaks and correct
as necessary. Each year of operation or if a problem is
suspected, check condition of check valve. Replace if
damaged or worn out.
6.
Keep all screws, bolts, and covers tightly
mounted. Check their conditions periodically.
WARNING:
Keep all screws, bolts and covers
properly tightened. If screws plates or covers
become loose personal injury or property damage
may occur.
Recommended interval of inspection and maintenance
Inspect and maintain the compressor within the period as described in the following table.
Part
Action
Daily
(before/after use)
Weekly
Monthly
Quarterly
Overall
Inspect for unusual
noise and vibration
-
-
-
Clean off dirt and
dust with dry air.
-
-
-
Air lines and fittings
Inspect for leakage
-
-
-
Air tank
Exhaust all air and
drain condensation
in the air tank. (open
the drain valve.)
-
-
-
Inspect for
scratches, dents, or
leakage.
-
-
-
Inspect rust, pin
holes, or other
imperfections that
could cause it to
become unsafe.
-
-
-
Bolts and nuts
Inspect for
tightness.
-
-
-
Handle
Wipe off oil and
grease.
-
-
-
Safety valve
Check function
-
-
-
Cut-out pressure
Check and adjust.
-
-
-
Air filter
Clean or replace if
necessary.
-
-
-
Lubrication
This air compressor is equipped with an Oil-Less pump
designed for durability and no maintenance.
Storage
Before you store the air compressor, make sure you do
the following:
Review the “MAINTENANCE” and “OPEATION”
sections and perform maintenance as necessary.
Be sure to drain water from the air tank.
Protect the air hose from damage (such as being
stepped on or run over).
Store the air compressor in a clean and dry location.