Makita AF506 AF506 Instruction Manual - Page 8

Maintenance

Page 8 highlights

1. Open the slide door and remove nails from the magazine. Maintenance of nailer Always check the tool for its overall condition and loose screws before operation. Tighten as required. With tool disconnected, make daily inspection to assure free movement of the contact element and trigger. Do not use tool if the contact element or trigger sticks or binds. When the tool is not to be used for an extended period of time, lubricate the tool using pneumatic tool oil and store the tool in a safe place. Avoid exposure to direct sunlight and/or humid or hot environment. 2. With the slide door kept open, pull the latch to open the door and then remove nails. 1 2 Maintenance of compressor, air set and air hose After operation, always drain the compressor tank and the air filter. If moisture is allowed to enter the tool, it may result in poor performance and possible tool failure. 1 ► 1 . Latch 2. Door MAINTENANCE ► 1 . Drain cock CAUTION: Always disconnect the hose before attempting to perform inspection or maintenance. 1 NOTICE: Never use gasoline, benzine, thinner, alcohol or the like. Discoloration, deformation or cracks may result. Nails Handle nail strips and their box carefully. If the nail strips have been handled roughly, they may be out of shape, causing poor nail feed. Avoid storing nails in a very humid or hot place or place exposed to direct sunlight. ► 1 . Air filter 8 ENGLISH

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

8
ENGLISH
1.
Open the slide door and remove nails from the
magazine.
2.
With the slide door kept open, pull the latch to
open the door and then remove nails.
1
2
1.
Latch
2.
Door
MAINTENANCE
CAUTION:
Always disconnect the hose
before attempting to perform inspection or
maintenance.
NOTICE:
Never use gasoline, benzine, thinner,
alcohol or the like. Discoloration, deformation or
cracks may result.
Nails
Handle nail strips and their box carefully. If the nail
strips have been handled roughly, they may be out of
shape, causing poor nail feed.
Avoid storing nails in a very humid or hot place or place
exposed to direct sunlight.
Maintenance of nailer
Always check the tool for its overall condition and loose
screws before operation. Tighten as required.
With tool disconnected, make daily inspection to assure
free movement of the contact element and trigger. Do not
use tool if the contact element or trigger sticks or binds.
When the tool is not to be used for an extended period
of time, lubricate the tool using pneumatic tool oil and
store the tool in a safe place. Avoid exposure to direct
sunlight and/or humid or hot environment.
Maintenance of compressor, air set
and air hose
After operation, always drain the compressor tank and
the air filter. If moisture is allowed to enter the tool, it may
result in poor performance and possible tool failure.
1
1.
Drain cock
1
1.
Air filter