Makita HR2651 OSHA Silica Compliance Catalog - Page 8

Drilling Applications

Page 8 highlights

CONCRETE APPLICATIONS DRILLING APPLICATIONS OSHA RULE TABLE 1: HANDHELD AND STAND-MOUNTED DRILLS MAKITA® DUST EXTRACTION OSHA COMPLIANT SOLUTIONS SDS-PLUS / SDS-MAX DRILLING (COMPATIBLE DUST EXTRACTORS) APPLICATION SDS-PLUS Drilling APPLICABLE TOOLS XRH011X, XRH01ZVX, XRH011TX DUST ATTACHMENT 199588-6 - Dust Case w/ Filter Cleaning Mechanism CONNECTION ADAPTER DUST EXTRACTOR DX01 - Dust Extractor Attachment with HEPA Filter N/A XRH08PTW, XRH10ZX, XRH10PTW, XRH12ZW, XRH12TW Required for Compliance Under OSHA Table 1 DX08 - Dust Extractor with HEPA Cleaning Mechanism OSHA 29 CFR 1926.1153 COMPLIANT YES Option 1, Under Table 1 of Specified Exposure Control Methods* YES Option 1, Under Table 1 of Specified Exposure Control Methods* SDS-PLUS Drilling HR2661, HR2651 N/A 135905-6 Dust Extraction Attachment YES w/HEPA Filter N/A Option 2, Performance (Objective Data)** SDS-PLUS Drilling XRH01, XRH03, XRH04, XRH05, XRH06, HR2475, HR2641, HR2811F, HR2631F XRH01, XRH08, XRH10 193472-7 Dust Extraction Attachment 195173-3 Dust Extraction Cup Included XCV10ZX 18V X2 LXT® (36V) BL™ 1/2 Gal. HEPA Filter Backpack Dust Extractor, AWS™ Capable REQUIRED SELF TESTING Option 3, Scheduled Self-Monitoring XRH12, XRH06, RH01, RH02, HR1840 198362-9 Dust Extraction Cup SDS-PLUS Drilling XRH01, XRH03, XRH04, XRH05, XRH06, HR2475, HR2641, HR2811F, HR2631F XRH12, XRH06, RH01, RH02, HR1840 193472-7 Dust Extraction Attachment 198362-9 Dust Extraction Cup XCV13Z 18V X2 LXT® Lithium-Ion (36V) Cordless/Corded 4 Gallon HEPA Filter Dry Dust Extractor/Vacuum SDS-MAX Drilling XRH01, XRH08, XRH10, HR2641 HR4002, HR4510C 195173-3 Dust Extraction Cup 196074-8 Dust Extraction Attachment Included XCV16ZX 18V X2 LXT® Lithium-Ion (36V) Brushless 4 Gallon HEPA Filter Dry Dust Extractor, AWS™ YES Option 1, Under Table 1 of Specified Exposure Control Methods* HR4013C, XRH07 196537-4 Dust Extraction Attachment HR5212C 196858-4 Dust Extraction Attachment *Additionally HEPA filtered vacuum is required when cleaning holes. **Compliant under Option 2, Objective Data of the OSHA standard for Occupational Exposure to Respirable Crystalline Silica (rule 1926.1153) when dust extractor is operated with the tested tool model and operated under conditions tested by Makita®. To see the test procedures go to makitatools.com/dustmanagement. Note: To ensure performance, verify that any engineer controls (accessory-components used with the dust collector/vacuum such as dust shrouds, dust extraction attachments, connectors) are used per manufacturer instructions and are securely attached to a compliant vacuum. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

APPLICATION
APPLICABLE TOOLS
DUST ATTACHMENT
CONNECTION ADAPTER
DUST EXTRACTOR
OSHA 29 CFR 1926.1153
COMPLIANT
SDS-PLUS
Drilling
XRH011X, XRH01ZVX,
XRH011TX
199588-6 - Dust Case w/ Filter
Cleaning Mechanism
Required for Compliance Under OSHA
Table 1
N/A
DX01 - Dust Extractor
Attachment with HEPA Filter
YES
Option 1, Under Table 1 of Specified
Exposure Control Methods*
XRH08PTW, XRH10ZX,
XRH10PTW, XRH12ZW,
XRH12TW
DX08 - Dust Extractor with
HEPA Cleaning Mechanism
YES
Option 1, Under Table 1 of Specified
Exposure Control Methods*
SDS-PLUS
Drilling
HR2661, HR2651
N/A
N/A
135905-6
Dust Extraction Attachment
w/HEPA Filter
YES
Option 2, Performance
(Objective Data)**
SDS-PLUS
Drilling
XRH01, XRH03, XRH04,
XRH05, XRH06, HR2475,
HR2641, HR2811F, HR2631F
193472-7
Dust Extraction Attachment
Included
XCV10ZX
18V X2 LXT
®
(36V) BL
1/2 Gal.
HEPA Filter Backpack Dust
Extractor, AWS
Capable
REQUIRED
SELF TESTING
Option 3, Scheduled
Self-Monitoring
XRH01, XRH08, XRH10
195173-3
Dust Extraction Cup
XRH12, XRH06, RH01, RH02,
HR1840
198362-9
Dust Extraction Cup
SDS-PLUS
Drilling
XRH01, XRH03, XRH04,
XRH05, XRH06, HR2475,
HR2641, HR2811F, HR2631F
193472-7
Dust Extraction Attachment
Included
XCV13Z
18V X2 LXT
®
Lithium-Ion (36V)
Cordless/Corded 4 Gallon HEPA
Filter Dry Dust Extractor/Vacuum
XCV16ZX
18V X2 LXT
®
Lithium-Ion (36V)
Brushless 4 Gallon HEPA Filter
Dry Dust Extractor, AWS
YES
Option 1, Under Table 1 of Specified
Exposure Control Methods*
XRH12, XRH06, RH01,
RH02, HR1840
198362-9
Dust Extraction Cup
XRH01, XRH08,
XRH10, HR2641
195173-3
Dust Extraction Cup
SDS-MAX
Drilling
HR4002, HR4510C
196074-8
Dust Extraction Attachment
HR4013C, XRH07
196537-4
Dust Extraction Attachment
HR5212C
196858-4
Dust Extraction Attachment
8
CONCRETE APPLICATIONS
DRILLING APPLICATIONS
OSHA RULE TABLE 1: HANDHELD AND STAND-MOUNTED DRILLS
MAKITA
®
DUST EXTRACTION OSHA COMPLIANT SOLUTIONS
SDS-PLUS / SDS-MAX DRILLING
(COMPATIBLE DUST EXTRACTORS)
*Additionally HEPA filtered vacuum is required when cleaning holes.
**Compliant under Option 2, Objective Data of the OSHA standard for Occupational Exposure to Respirable Crystalline Silica (rule 1926.1153) when dust extractor is operated with the tested tool model and
operated under conditions tested by Makita
®
. To see the test procedures go to makitatools.com/dustmanagement.
Note: To ensure performance, verify that any engineer controls (accessory-components used with the dust collector/vacuum such as dust shrouds, dust extraction attachments, connectors) are used per
manufacturer instructions and are securely attached to a compliant vacuum.