ENGLISH (Original instructions) SPECIFICATIONS Model: RW01 Fastening capacities (with manual retightening) Standard bolt High tensile bolt M5 - M12 (3/16" - 1/2") M5 - M10 (3/16" - 3/8") Square drive 6.35mm (1/4") , 9.5mm (3/8") No load speed 0 - 800 /min Maximum fastening torque 47.5 N•m (35 ft•lbs) Overall length 341 mm (13-7/16") Rated voltage D.C. 10.8 V - 12 V max Net weight 1.0 - 1.2 kg (2.3 - 2.7 lbs) • Due to our continuing program of research and development, the specifications herein are subject to change without notice. • Specifications and battery cartridge may differ from country to country. • The weight may differ depending on the attachment(s), including the battery cartridge. The lightest and heaviest combinations, according to EPTA-Procedure 01/2014, are shown in the table. Applicable battery cartridge and charger Battery cartridge BL1016 / BL1021B / BL1041B Charger DC10SB / DC10WD / DC18RE • Some of the battery cartridges and chargers listed above may not be available depending on your region of residence. WARNING: Only use the battery cartridges and chargers listed above. Use of any other battery cartridges and chargers may cause injury and/or fire. SAFETY WARNINGS General power tool safety warnings WARNING: Read all safety warnings, instructions, illustrations and specifications provided with this power tool. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. The term "power tool" in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool. Work area safety 1. Keep work area clean and well lit. Cluttered or dark areas invite accidents. 2. Do not operate power tools in explosive atmo- spheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes. 3. Keep children and bystanders away while operating a power tool. Distractions can cause you to lose control. Electrical Safety 1. Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching outlets will reduce risk of electric shock. 2. Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded. 3. Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock. 4. Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock. 5. When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock. 6. If operating a power tool in a damp location is unavoidable, use a ground fault circuit interrupter (GFCI) protected supply. Use of a GFCI reduces the risk of electric shock. 7. Power tools can produce electromagnetic fields (EMF) that are not harmful to the user. However, users of pacemakers and other similar medical devices should contact the maker of their device and/ or doctor for advice before operating this power tool. 2 ENGLISH

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

2
ENGLISH
ENGLISH (Original instructions)
SPECIFICATIONS
Model:
RW01
Fastening capacities
(with manual retightening)
Standard bolt
M5 - M12 (3/16" - 1/2")
High tensile bolt
M5 - M10 (3/16" - 3/8")
Square drive
6.35mm (1/4") , 9.5mm (3/8")
No load speed
0 - 800 /min
Maximum fastening torque
47.5 N•m (35 ft•lbs)
Overall length
341 mm (13-7/16")
Rated voltage
D.C. 10.8 V - 12 V max
Net weight
1.0 - 1.2 kg (2.3 - 2.7 lbs)
Due to our continuing program of research and development, the specifications herein are subject to change without notice.
Specifications and battery cartridge may differ from country to country.
The weight may differ depending on the attachment(s), including the battery cartridge. The lightest and heavi
-
est combinations, according to EPTA-Procedure 01/2014, are shown in the table.
Applicable battery cartridge and charger
Battery cartridge
BL1016 / BL1021B / BL1041B
Charger
DC10SB / DC10WD / DC18RE
Some of the battery cartridges and chargers listed above may not be available depending on your region of
residence.
WARNING:
Only use the battery cartridges and chargers listed above.
Use of any other battery cartridges
and chargers may cause injury and/or fire.
SAFETY WARNINGS
General power tool safety warnings
WARNING:
Read all safety warnings, instruc-
tions, illustrations and specifications provided
with this power tool.
Failure to follow all instructions
listed below may result in electric shock, fire and/or
serious injury.
Save all warnings and instruc-
tions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-operated
(cordless) power tool.
Work area safety
1.
Keep work area clean and well lit.
Cluttered or
dark areas invite accidents.
2.
Do not operate power tools in explosive atmo-
spheres, such as in the presence of flammable
liquids, gases or dust.
Power tools create sparks
which may ignite the dust or fumes.
3.
Keep children and bystanders away while
operating a power tool.
Distractions can cause
you to lose control.
Electrical Safety
1.
Power tool plugs must match the outlet. Never modify
the plug in any way. Do not use any adapter plugs
with earthed (grounded) power tools.
Unmodified plugs
and matching outlets will reduce risk of electric shock.
2.
Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators.
There is an increased risk of elec
-
tric shock if your body is earthed or grounded.
3.
Do not expose power tools to rain or wet con-
ditions.
Water entering a power tool will increase
the risk of electric shock.
4.
Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges
or moving parts.
Damaged or entangled cords
increase the risk of electric shock.
5.
When operating a power tool outdoors, use an
extension cord suitable for outdoor use.
Use of a cord
suitable for outdoor use reduces the risk of electric shock.
6.
If operating a power tool in a damp location is
unavoidable, use a ground fault circuit inter-
rupter (GFCI) protected supply.
Use of a GFCI
reduces the risk of electric shock.
7.
Power tools can produce electromagnetic fields
(EMF) that are not harmful to the user.
However,
users of pacemakers and other similar medical
devices should contact the maker of their device and/
or doctor for advice before operating this power tool.