Maytag MED5630H Installation Instructions - Page 20

Install Vent System

Page 20 highlights

Long Vent System Chart Number of 90° elbows Type of vent Angled hoods 0 Rigid metal 160 ft. (48.8 m) 1 Rigid metal 150 ft. (45.7 m) 2 Rigid metal 140 ft. (42.7 m) 3 Rigid metal 130 ft. (39.6 m) 4 Rigid metal 120 ft. (36.6 m) To determine if your model has a long vent system, refer to the type code located on the serial number plate in the inner door well. Example: An electric model would be DJAV - ELE - XXXXXXX-XXX. A gas model would be DJAV - NAT - XXXXXXXXXX. NOTE: For long vent systems, use of box/louvered hoods will improve venting regardless of length. 2. Connect vent to exhaust hood Vent must fit over the exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent, because they can catch lint. Install Vent System 1. Install exhaust hood Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood. 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

20
Long Vent System Chart
Number of 90°
elbows
Type of vent
Angled hoods
0
Rigid metal
160 ft. (48.8 m)
1
Rigid metal
150 ft. (45.7 m)
2
Rigid metal
140 ft. (42.7 m)
3
Rigid metal
130 ft. (39.6 m)
4
Rigid metal
120 ft. (36.6 m)
Install Vent System
1.
Install exhaust hood
2.
Connect vent to exhaust hood
Install exhaust hood and use caulking compound to seal exterior
wall opening around exhaust hood.
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location using
straightest path possible. Avoid 90° turns. Use clamps to seal all
joints. Do not use duct tape, screws, or other fastening devices
that extend into interior of vent to secure vent, because they can
catch lint.
To determine if your model has a long vent system, refer to
the type code located on the serial number plate in the inner
door well. Example: An electric model would be DJ
AV
– ELE –
XXXXXXX-XXX. A gas model would be DJ
AV
– NAT – XXXXXXX-
XXX.
NOTE:
For long vent systems, use of box/louvered hoods will