LEVEL DRYER 1. Level dryer Place level here Check levelness of dryer from side to side. Repeat from front to back. NOTE: The dryer must be level for the moisture sensing system to operate correctly. Not Level LEVEL 2. Adjust leveling legs Not Level If dryer is not level, prop up using a wood block, use wrench to adjust legs up or down, and check again for levelness. Once dryer is level, make sure all four legs are snug against the floor and the dryer does not rock. COMPLETE INSTALLATION CHECKLIST ‰‰Check that all parts are now installed. If there is an extra part, go back through steps to see what was skipped. ‰‰Check that you have all of your tools. ‰‰Dispose of/recycle all packaging materials. ‰‰Be sure the water faucets are on. ‰‰Check for leaks around "Y" connector, faucet, and hoses. ‰‰Check dryer's final location. Be sure vent is not crushed or kinked. ‰‰Check that dryer is level. See "Level Dryer." ‰‰Remove film on console and any tape remaining on dryer. ‰‰Wipe dryer drum interior thoroughly with a damp cloth to remove any dust. ‰‰Read "Dryer Use" in your Use and Care Guide. ‰‰If you live in a hard water area, use of a water softener is recommended to control the buildup of scale through the water system in the dryer. Over time, the buildup of lime scale may clog different parts of the water system, which will reduce product performance. Excessive scale buildup may lead to the need for certain part replacement or repair. Electric Models: ‰‰Plug into a grounded outlet. Gas Models: ‰‰Plug into a grounded outlet. ‰‰Check that gas supply is on. ‰‰Check for leaks. ‰‰ Check to be sure that the flexible gas line is not crushed or kinked. All Models: ‰‰Select a Timed Dry heated cycle and start dryer. Do not select Air Only Temperature setting. If dryer will not start, check the following: • Controls are set in a running or On position. • Start button has been pressed firmly. • Dryer is plugged into an outlet and/or electrical supply is connected. • Household fuse is intact and tight, or circuit breaker has not tripped. • Dryer door is closed. This dryer automatically runs an installation diagnostic routine at the start of its first cycle. NOTE: You may notice an odor when dryer is first heated. This odor is common when heating element is first used. The odor will go away. 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

23
If dryer is not level, prop up using a wood block, use wrench to
adjust legs up or down, and check again for levelness. Once
dryer is level, make sure all four legs are snug against the floor
and the dryer does not rock.
LEVEL DRYER
Check levelness of dryer from side to side. Repeat from front
to back.
NOTE:
The dryer must be level for the moisture sensing
system to operate correctly.
COMPLETE INSTALLATION CHECKLIST
±
Check that all parts are now installed. If there is an extra part,
go back through steps to see what was skipped.
±
Check that you have all of your tools.
±
Dispose of/recycle all packaging materials.
±
Be sure the water faucets are on.
±
Check for leaks around “Y” connector, faucet, and hoses.
±
Check dryer’s final location. Be sure vent is not crushed or
kinked.
±
Check that dryer is level. See “Level Dryer.”
±
Remove film on console and any tape remaining on dryer.
±
Wipe dryer drum interior thoroughly with a damp cloth to
remove any dust.
±
Read “Dryer Use” in your Use and Care Guide.
±
If you live in a hard water area, use of a water softener is
recommended to control the buildup of scale through the
water system in the dryer. Over time, the buildup of lime scale
may clog different parts of the water system, which will reduce
product performance. Excessive scale buildup may lead to the
need for certain part replacement or repair.
Electric Models:
±
Plug into a grounded outlet.
Gas Models:
±
Plug into a grounded outlet.
±
Check that gas supply is on.
±
Check for leaks.
±
Check to be sure that the flexible gas line is not crushed or
kinked.
All Models:
±
Select a Timed Dry heated cycle and start dryer. Do not select
Air Only Temperature setting.
If dryer will not start, check the following:
• Controls are set in a running or On position.
• Start button has been pressed firmly.
• Dryer is plugged into an outlet and/or electrical supply is
connected.
• Household fuse is intact and tight, or circuit breaker has not
tripped.
• Dryer door is closed.
This dryer automatically runs an installation diagnostic routine at
the start of its first cycle.
NOTE:
You may notice an odor when dryer is first heated. This
odor is common when heating element is first used. The odor will
go away.
Not Level
LEVEL
Not Level
2.
Adjust leveling legs
1.
Level dryer
Place