Maytag MEDB850WB Installation Instructions - Page 14

Whirlpool, System, Chart

Page 14 highlights

If you prefer, dryer may be converted to exhaust through the bottom. You must contact your local dealer to have dryer converted. Special provisions for mobile homes: Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside. /_ A B A. Standard rear offset exhaust installation B. Bottom exhaust installation Alternate installations for close clearances Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer's instructions. A B A. Over-the-top installation (also available with one offset elbow) B. Periscope installation NOTE: The following kits for close clearance alternate installations are available for purchase. Contact your local dealer. [] Over-the-Top Installation: Part Number 4396028 [] Periscope Installation (For use with dryer vent to wall vent mismatch): Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch Part Number 4396011 - 18" (460 mm) to 29" (737 mm) mismatch Part Number 4396014 - 29" (737 mm) to 50" (1270 mm) mismatch Mobile Home Exhaust installation Determine vent path: [] Select route that will provide straightest path outdoors. and most direct [] Plan installation to use fewest number of elbows and turns. [] When using elbows or making turns, allow as much room as possible. [] Bend vent gradually to avoid kinking. [] Use as few 90 ° turns as possible. Determine vent length and elbows needed for best drying performance: [] Use following Vent System Chart to determine type of vent material and hood combinations acceptable to use. NOTE: Do not use vent runs longer than those specified in Vent System Chart. Exhaust systems longer than those specified will: [] Shorten life of dryer. [] Reduce performance, resulting in longer drying times and increased energy usage. The Vent System Charts provide venting requirements that will help achieve best drying performance. Whirlpool Vent System Chart Number of 90 ° elbows Type of vent Box/Iouvered hoods Angled hoods 0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m) 1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m) 2 Rigid metal 44 ft. (13.4m) 38 ft. (11.6m) 3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

If you prefer, dryer
may be converted
to exhaust
through
the bottom.
You must contact
your local dealer to have dryer
converted.
A
B
A. Standard
rear offset
exhaust
installation
B. Bottom
exhaust
installation
Alternate
installations
for
close
clearances
Venting systems
come in many varieties.
Select the type
best
for your installation.
Two close-clearance
installations
are shown.
Refer to the manufacturer's
instructions.
A
B
A. Over-the-top
installation
(also available
with one offset elbow)
B. Periscope
installation
NOTE: The following
kits for close clearance
alternate
installations
are available for purchase.
Contact
your local dealer.
[]
[]
Over-the-Top
Installation:
Part Number
4396028
Periscope
Installation
(For use with dryer vent to wall vent
mismatch):
Part Number
4396037
- 0" (0 mm) to 18" (460 mm) mismatch
Part Number
4396011
- 18" (460 mm) to 29" (737 mm)
mismatch
Part Number 4396014
- 29" (737 mm) to 50" (1270 mm)
mismatch
Special
provisions
for
mobile
homes:
Exhaust vent must be securely fastened
to a noncombustible
portion of mobile home and must not terminate
beneath the
mobile
home. Terminate
exhaust
vent outside.
/_
Mobile Home Exhaust installation
Determine
vent
path:
[]
Select route that will provide straightest
and most direct
path outdoors.
[]
Plan installation
to use fewest
number
of
elbows
and turns.
[]
When using
elbows
or making turns,
allow as much room
as possible.
[]
Bend vent gradually
to avoid
kinking.
[]
Use as few 90 ° turns as possible.
Determine
vent
length
and
elbows
needed
for
best
drying
performance:
[]
Use following
Vent System Chart to determine
type
of vent
material
and hood combinations
acceptable
to use.
NOTE: Do not use vent runs longer than those
specified
in Vent System Chart.
Exhaust systems
longer than those
specified
will:
[]
Shorten
life
of dryer.
[]
Reduce
performance,
resulting
in
longer
drying
times
and increased
energy
usage.
The Vent System Charts
provide venting
requirements
that
will help achieve
best drying performance.
Whirlpool
Vent
System
Chart
Number
of
Type
Box/Iouvered
Angled
90 ° elbows
of vent
hoods
hoods
0
Rigid
metal
64 ft. (20 m)
58 ft. (17.7 m)
1
Rigid
metal
54 ft. (16.5 m)
48 ft. (14.6 m)
2
Rigid
metal
44 ft. (13.4m)
38 ft. (11.6m)
3
Rigid
metal
35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid
metal
27 ft. (8.2 m)
21 ft. (6.4 m)
14