Maytag MGC6536BDW Installation Manual - Page 11

Burner Performance

Page 11 highlights

Burner Performance CAUTION: Never cover control knobs or surrounding control surface with utensils, towels, or other objects. Never obstruct free air passage past the control knobs. The knob openings have been sized to properly control air entry to the interior of the appliance during operation. This appliance has no air shutters. Primary air adjustments are unnecessary. The burners are designed to provide optimum aeration for all gases without air 5 BURNER MODEL (36² Wide) shutters. When operating properly, burners should produce clearly defined, even blue flames. If the flames have yellow tips or are hazy and otherwise appear to have insufficient air, obtain the services of a qualified service technician. Some yellow tipping on LP gas is normal. Specified input rates are as shown in figures 16 and 17 below. 4 BURNER MODEL (30² Wide) FIGURE 16 MAYTAG 36² INPUT RATES - NATURAL GAS / LP GAS (BTU/HR) BURNER LOCATION Right Front Right Rear Left Front Left Rear Center Hi 12,500 / 10,500 9,200 / 9,100 9,200 / 9,100 10,500 / 9,100 5,000 / 4,000 Lo 1300 / 1300 1300 / 1300 1300 / 1300 1300 / 1300 650 / 650 FIGURE 17 MAYTAG 30² INPUT RATES - NATURAL GAS / LP GAS (BTU/HR) BURNER LOCATION Right Front Right Rear Left Front Left Rear Center Hi 12,500 / 10,500 9,200 / 9,100 9,200 / 9,100 5000 / 4000 ----------- Lo 1300 / 1300 1300 / 1300 1300 / 1300 650 / 650 ----------- 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

11
Burner Performance
CAUTION:
Never cover control knobs or surrounding
control surface with utensils, towels, or other objects.
Never obstruct free air passage past the control knobs.
The knob openings have been sized to properly control air
entry to the interior of the appliance during operation.
This appliance has no air shutters. Primary air
adjustments are unnecessary. The burners are designed
to provide optimum aeration for all gases without air
shutters. When operating properly, burners should
produce clearly defined, even blue flames. If the flames
have yellow tips or are hazy and otherwise appear to
have insufficient air, obtain the services of a qualified
service technician. Some yellow tipping on LP gas is
normal.
Specified input rates are as shown in figures 16 and 17
below.
BURNER LOCATION
Hi
Lo
Right Front
12,500 / 10,500
1300 / 1300
Right Rear
9,200 /
9,100
1300 / 1300
Left Front
9,200 /
9,100
1300 / 1300
Left Rear
5000 /
4000
650 /
650
Center
-----------
-----------
INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)
FIGURE 16
5 BURNER MODEL (36
±
Wide)
MAYTAG 30
±
FIGURE 17
MAYTAG 36
±
BURNER LOCATION
Hi
Lo
Right Front
12,500 / 10,500
1300 / 1300
Right Rear
9,200 /
9,100
1300 / 1300
Left Front
9,200 /
9,100
1300 / 1300
Left Rear
10,500 /
9,100
1300 / 1300
Center
5,000 /
4,000
650 /
650
INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)
4 BURNER MODEL (30
±
Wide)