Maytag MGD8630HW Installation Instructions - Page 16
Optional External Ground for 3-Wire
View all Maytag MGD8630HW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
3. Connect neutral wire 2. Connect neutral ground wire and neutral wire Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B), hook facing right. Squeeze hooked end together. Tighten screw. 4. Connect remaining wires Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center terminal block screw (B). Tighten screw. 3. Connect remaining wires Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now go to "Venting Requirements." Place ends of remaining wires under outer terminal block screws. Tighten screws. Optional External Ground for 3-Wire Connection (Power Supply Cord Shown) IMPORTANT: You must verify with a qualified electrician that this grounding method is acceptable before connecting. 4. Connect external ground wire 1. Prepare to connect neutral ground wire and neutral wire Install the correct strain relief for your electrical connection method, as shown on page 12 or 14. Remove center terminal block screw (B). Remove neutral ground wire (E) from green external ground conductor screw (A). 16 Connect a separate copper ground wire (G) under the green external ground conductor screw (A) to an adequate ground. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now go to "Venting Requirements."