Metabo ASR 35 ACP HEPA Operating Instructions - Page 16

Special safety instructions for, ASR 35 M ACP, ASR 35 H ACP

Page 16 highlights

en ENGLISH Acids, acetone and solvents can corrode the device components. Prior to any servicing work, clean the device. Switch off the device after each use and pull out the mains plug. Steam cleaners and high-pressure cleaners must not be used to clean the vacuum cleaner. The inside of the cover must always be kept dry. Mould contamination can result if the device is not cleaned for an extended period, especially if used in areas where foodstuffs are processed: Always clean and disinfect the vacuum cleaner immediately after use. Never open the device outdoors during rain or storms. Do not use the device outdoors in cold weather. The device must not be operated in areas with an explosion hazard. Ensure that the vacuum cleaner is steady. If the extracted air is discharged into the room, ensure there is an adequate air change rate (L) in the room. Observe the regulations that apply in your country. Caution! This device contains dust that is harmful to health. Discharge and maintenance operations (including disposal of the dust collection containers) must only be carried out by qualified specialists wearing appropriate protective clothing and equipment. Warning - general danger! 16 Caution! Do not use the device until you have read the operating Instructions. WARNING - Operating staff must be provided with appropriate instruction on how to use this vacuum cleaner. Special safety instructions for ASR 35 M ACP: Warning sign for machines with dust class M: During discharge and maintenance operations, note the following: Clean the device before opening it. Wear a dust mask. Avoid exposing third parties to dust. Provide local filtered forced ventilation. Then clean the maintenance area. Do not operate the device without the complete filtration system. (filter cassettes and PE disposal bags). According to tests carried out as per EN 60335 section 1 and 69, the device also meets electrical safety requirements relating to the extraction of a water-air mixture. Special safety instructions for ASR 35 H ACP: Warning sign for machines with dust class H: e CAUTION: This device contains dust that is harmful to health. Discharge and maintenance operations, including disposal of

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

ENGLISH
en
16
Acids, acetone and solvents can
corrode the device components.
Prior to any servicing work,
clean the device. Switch off the
device after each use and pull out
the mains plug.
Steam cleaners and high-pressure
cleaners must not be used to clean
the vacuum cleaner.
The inside of the cover must
always be kept dry.
Mould contamination can result if
the device is not cleaned for an
extended period, especially if used
in areas where foodstuffs are
processed: Always clean and
disinfect the vacuum cleaner
immediately after use.
Never open the device outdoors
during rain or storms.
Do not use the device outdoors in
cold weather.
The device must not be operated in
areas with an explosion hazard.
Ensure that the vacuum cleaner is
steady.
If the extracted air is discharged
into the room, ensure there is an
adequate air change rate (L) in the
room. Observe the regulations that
apply in your country.
Caution! This device contains
dust that is harmful to health.
Discharge and maintenance
operations (including disposal of
the dust collection containers)
must only be carried out by
qualified specialists wearing
appropriate protective clothing and
equipment.
Warning - general danger!
Caution! Do not use the
device until you have read the
operating Instructions.
WARNING - Operating staff must
be provided with appropriate
instruction on how to use this
vacuum cleaner.
Special safety instructions for
ASR 35 M ACP:
Warning sign for machines with
dust class M:
During discharge and maintenance
operations, note the following:
Clean the device before opening it.
Wear a dust mask. Avoid exposing
third parties to dust. Provide local
filtered forced ventilation. Then
clean the maintenance area.
Do not operate the device without
the complete filtration system.
(filter cassettes and PE disposal
bags).
According to tests carried out as
per EN 60335 section 1 and 69, the
device also meets electrical safety
requirements relating to the
extraction of a water-air mixture.
Special safety instructions for
ASR 35 H ACP:
Warning sign for machines with
dust class H:
CAUTION: This device contains
dust that is harmful to health.
Discharge and maintenance
operations, including disposal of
e