Metabo BHA 18 LTX Operating Instructions 2 - Page 12

Initial Operation

Page 12 highlights

17027010_0311 BHA 18 LT LTX 36 LTX Compact.book Seite 12 Donnerstag, 10. März 2011 10:29 10 ENG ENGLISH 7 Initial Operation 7.1 Assembly of the additional handle For safety reasons, always use the additional handle (3) supplied. Open the clamping ring by turning the additional handle (3) anticlockwise. Push the additional handle onto the collar of the machine. Insert the depth stop (1) . Securely tighten the additional handle at the angle required for the application. 7.2 Carrying strap If necessary, hang the hook on the Metabo carrying strap (6) on the eyelet (7). Set the carrying strap (6) to the desired length. Carrying: To prevent unintentional start-up, move the rotation selector switch (8) to centre position (transporting safety device). Never carry with a tool inserted. The machine must only be carried with the Metabo carrying strap (6) across chest and back (illustration a, page 3). Hold the machine steady. The machine must NOT be carried with the carrying strap (6) around your neck (illustration b, page 3). 8 Use 8.1 Depth Stop Setting Release the additional handle (17). Set depth stop (1) to the desired drilling depth and retighten additional handle. 2. Long continuous overloading of the machine will activate the temperature cut-out. Leave the machine or battery pack to cool. Note: If the battery pack feels very warm, the pack will cool more quickly in your "AIR COOLED" charger. Note: The machine will cool more quickly if you operate it at idling speed. 3. If the current is too high (for example, if the machine seizes continuously for long periods), the machine switches off. Switch off the machine at the trigger (9) . Then continue working as normal. Try to prevent the machine from seizing. 8.3 Battery pack Charge the battery pack before use (11) . If performance diminishes, recharge the battery pack. The ideal storage temperature is between 10°C and 40°C. "Li-Power" li-ion battery packs have a capacity and signal indicator: (13) - Press the button (12) , the LEDs indicate the charge level. - If one LED is flashing, the battery pack is almost flat and must be recharged. 8.4 Removing and inserting the battery pack Removal: Press the battery pack release button (10) and pull out the battery pack (11) from the back. Inserting: Slide in the battery pack (11) until it engages. 8.2 Automatic protection mode If the machine switches off automatically, the machine electronics have activated automatic protection mode. A warning signal sounds (continuous beeping). The beeping stops after a maximum of 30 seconds or when the trigger is released (9) . Causes and remedies: 1. Battery pack almost flat (the electronics prevent the battery pack from discharging totally and avoid irreparable damage). If one LED is flashing (13) , the battery pack is almost flat. If necessary, press the (12) button and check the LEDs (13) to see the charge level. If the battery pack is almost flat, it must be recharged. 8.5 Setting the direction of rotation, engaging the transporting safety device (switch-on lock) Do not activate the rotation selector switch (8) unless the motor has completely stopped! Set the rotation selector switch (8). See page 3 (please unfold). R = Clockwise setting L = Counter-clockwise setting 0 = Middle position: transportation safety device (Switch-on lock) set 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

12
ENGLISH
ENG
7.1
Assembly of the
additional handle
For safety reasons, always use the addi-
tional handle (3) supplied.
Open the clamping ring by turning the additional
handle (3) anticlockwise. Push the additional
handle onto the collar of the machine. Insert the
depth stop (1) . Securely tighten the additional
handle at the angle required for the application.
7.2
Carrying strap
If necessary, hang the hook on the Metabo
carrying strap (6) on the eyelet (7). Set the carrying
strap (6) to the desired length.
Carrying:
To prevent unintentional start-up, move the
rotation selector switch (8) to centre posi-
tion (transporting safety device).
Never carry with a tool inserted.
The machine must only be carried with the
Metabo carrying strap (6) across chest and
back (illustration a, page 3). Hold the machine
steady.
The machine must NOT be carried with the
carrying strap (6) around your neck (illustration b,
page 3).
8.1
Depth Stop Setting
Release the additional handle (17). Set depth stop
(1)
to the desired drilling depth and retighten addi-
tional handle.
8.2
Automatic protection mode
If the machine switches off automatically, the
machine electronics have activated auto-
matic protection mode. A warning signal sounds
(continuous beeping). The beeping stops after a
maximum of 30 seconds or when the trigger is
released (9) .
Causes and remedies:
1.
Battery pack almost flat
(the electronics
prevent the battery pack from discharging
totally and avoid irreparable damage).
If one LED is flashing (13) , the battery pack is
almost flat. If necessary, press the (12)
button
and check the LEDs (13)
to see the charge
level. If the battery pack is almost flat, it must
be recharged.
2.
Long continuous overloading of the machine
will activate the
temperature cut-out
.
Leave the machine or battery pack to cool.
Note:
If the battery pack feels very warm, the
pack will cool more quickly in your "AIR
COOLED" charger.
Note:
The machine will cool more quickly if you
operate it at idling speed.
3.
If the
current is too high
(for example, if the
machine seizes continuously for long periods),
the machine switches off.
Switch off the machine at the trigger (9) . Then
continue working as normal. Try to prevent the
machine from seizing.
8.3
Battery pack
Charge the battery pack before use (11) .
If performance diminishes, recharge the
battery pack.
The ideal storage temperature is between 10°C
and 40°C.
"Li-Power"
li-ion battery packs
have a
capacity and signal indicator: (13)
- Press the button
(12) , the LEDs indicate the
charge level.
-
If one LED is flashing, the battery pack is almost
flat and must be recharged.
8.4
Removing and inserting the
battery pack
Removal:
Press the battery pack release button (10) and pull
out the battery pack
(11)
from the back
.
Inserting:
Slide in the battery pack
(11)
until it engages.
8.5
Setting the direction of rotation,
engaging the transporting safety device
(switch-on lock)
Do not activate the rotation selector switch
(8) unless the motor has completely
stopped!
Set the rotation selector switch (8).
See page 3 (please unfold).
R
=
Clockwise setting
L
=
Counter-clockwise setting
0
=
Middle position: transportation safety
device
(Switch-on lock) set
7
Initial Operation
8
Use
17027010_0311 BHA 18 LT LTX 36 LTX Compact.book
Seite 12
Donnerstag, 10. März 2011
10:29 10