Miele CVA 6800 Product Manual - Page 84
Ventilation 84, Installation 84, and +100°F/38 °C. - built in coffee machine
View all Miele CVA 6800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
Installation Ventilation When installing the coffee system, make sure that it is sufficiently ventilated at the back so that steam and hot air can escape. The ventilation openings in the surrounding cabinets and the space below the ceiling must be at least 78 3/4"² (200 cm²). Otherwise condensation can form, causing damage to the coffee system or the surrounding cabinets. Installation Make sure no power is supplied to the unit. The same applies in the event of disassembly! When built into cabinetry, only use the coffee machine in ambient temperatures between +50°F/10°C and +100°F/38 °C. You will need two Allen wrenches size 3 and 5 for the installation. To align the appliance door flush with the kitchen cabinetry, there must be a sealing strip around the installation recess; otherwise, a sealing strip must be put in place around the appliance. ^ If there is no sealing strip around the installation recess, stick the Miele sealing strip onto the appliance from behind before putting it into the recess. The sealing strip is available from Miele. 84