Active charcoal filter 19, Operation / Reprogramming
View all Miele DA 5321 W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Cleaning and Care Active charcoal filter In recirculation mode an active charcoal filter must be used in addition to the grease filters. It is designed to absorb cooking odors. The active charcoal filter will be replaced in the canopy above the grease filters. Replacement active charcoal filters can be ordered from Miele. ^ Remove the grease filters to access the charcoal filter. See "Cleaning and Care". ^ Insert the charcoal filter. Before using: ^ Program the charcoal filter timer, see "Operation / Reprogramming the charcoal filter timer". Replace the active charcoal filter when the charcoal filter indicator lights, at least every 6 months or when they no longer absorb odors efficiently. ^ After replacing the charcoal filter, press and hold the charcoal filter button for about 3 seconds to reset the charcoal filter timer. The indicator light will go out. If the charcoal filter is replaced before the timer has reached its maximum, the charcoal filter button should be pressed for 6 seconds to reset the counter to zero. 19