Installation Plywood backing The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage. If plywood backing is not needed, proceed to the included "Installation diagram". To install a plywood backing  Make a cutting line 3" (76 mm) above and 3" (76 mm) below the outline of the retaining plate.  Find the studs  to the left and right of the mounting location by tapping the wall or using a stud finder.  Mark a vertical cutting line along the center of each stud. CAUTION: When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.  Remove the drywall between the cutting lines and replace it with plywood  of a matching thickness (min. ½" (13 mm) thick). Tape the joints and refinish the wall.  Proceed to the enclosed "Installation diagram" to complete the installation.  Determine and mark the location of the retaining plate  for the canopy as outlined on the "Installation diagram". 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Installation
30
Plywood backing
The majority of the weight of the
installed ventilation system will be
supported by the lower retaining
plate. It must be firmly attached to
the stud framing behind the drywall.
If studs are not available in the
required locations, a plywood
backing (min.
½
" (13 mm) thick)
spanning at least two studs must be
installed.
Failure to adequately support the
weight as stated may result in the
ventilation system falling off the wall,
causing personal injury and property
damage.
If plywood backing is not needed,
proceed to the included "Installation
diagram".
To install a plywood backing
Determine and mark the location of
the retaining plate
for the canopy
as outlined on the "Installation
diagram".
Make a cutting line 3" (76 mm) above
and 3" (76 mm) below the outline of
the retaining plate.
Find the studs
to the left and right
of the mounting location by tapping
the wall or using a stud finder.
Mark a vertical cutting line along the
center of each stud.
CAUTION: When cutting or drilling
into the wall or ceiling, do not
damage electrical wiring and other
hidden utilities.
Remove the drywall between the
cutting lines and replace it with
plywood
of a matching thickness
(min.
½
" (13 mm) thick). Tape the
joints and refinish the wall.
Proceed to the enclosed "Installation