Miele EVS 6114 Operating and Installation instructions - Page 33

Contact Miele Technical Service to replace it., utes. An acoustic tone

Page 33 highlights

Frequently Asked Questions Problem Possible cause and solution There is a film of oil on the glass lid and in the drawer. The oil in the vacuum pump has become extremely hot.  Clean the drawer and leave it to cool down for 1 hour before starting another vacuuming process.  When carrying out a number of consecutive vacuuming processes, wait a minimum of 2 minutes between each process to prevent the oil from overheating again.  If the fault occurs again, contact Miele Technical Service. The vacuuming process The required vacuum could not be achieved. is canceled after 2 min-  Switch the drawer off and back on again. utes. An acoustic tone  Start the vacuuming process again, selecting a dif- sounds and the  sym- ferent vacuum level if necessary. bol lights up red. After intensive use of the drawer, the oil in the vac- uum pump has severely overheated.  Leave the drawer to cool for an hour before start- ing another vacuuming process.  When carrying out a number of consecutive vacu- uming processes, wait a minimum of 2 minutes between each process to prevent the oil from overheating again. The vacuuming process The glass lid is not sitting evenly. There is an object, is canceled after 5 sec- e.g., the edge of a bag, or some soiling on the sur- onds. An acoustic tone face of the chamber seal. sounds and the  sym-  Remove the obstruction and/or the soiling. bol lights up red.  Close the glass lid and press it down lightly for ap- prox. 5 seconds. The chamber seal is not fitted correctly.  Press the chamber seal in all the way round to make sure it is fitted evenly. The chamber seal is damaged, e.g., cracks can be seen.  Contact Miele Technical Service to replace it. 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

Frequently Asked Questions
33
Problem
Possible cause and solution
There is a film of oil on
the glass lid and in the
drawer.
The oil in the vacuum pump has become extremely
hot.
Clean the drawer and leave it to cool down for
1 hour before starting another vacuuming process.
When carrying out a number of consecutive vacu-
uming processes, wait a minimum of 2 minutes
between each process to prevent the oil from
overheating again.
If the fault occurs again, contact Miele Technical
Service.
The vacuuming process
is canceled after 2 min-
utes. An acoustic tone
sounds and the
 sym-
bol lights up red.
The required vacuum could not be achieved.
Switch the drawer off and back on again.
Start the vacuuming process again, selecting a dif-
ferent vacuum level if necessary.
After intensive use of the drawer, the oil in the vac-
uum pump has severely overheated.
Leave the drawer to cool for an hour before start-
ing another vacuuming process.
When carrying out a number of consecutive vacu-
uming processes, wait a minimum of 2 minutes
between each process to prevent the oil from
overheating again.
The vacuuming process
is canceled after 5 sec-
onds. An acoustic tone
sounds and the
 sym-
bol lights up red.
The glass lid is not sitting evenly. There is an object,
e.g., the edge of a bag, or some soiling on the sur-
face of the chamber seal.
Remove the obstruction and/or the soiling.
Close the glass lid and press it down lightly for ap-
prox. 5 seconds.
The chamber seal is not fitted correctly.
Press the chamber seal in all the way round to
make sure it is fitted evenly.
The chamber seal is damaged, e.g., cracks can be
seen.
Contact Miele Technical Service to replace it.