Motorola mT2a User Guide - Page 22

Installation 2: Install over European wall plate with 65mm offset

Page 22 highlights

WallPlate Installation Installation 2: Install over European wall plate with 65mm offset The European style wall plate is comprised of four primary parts; the box, the modular connector, mounting bracket for the modular connector, and the outer plastic cover. The decorative plastic cover can be discarded and replaced by the m2a WallPlate. Variance from Country to Country 1. Typical dimensions of the telco box are 70mm square; 85mm square, or 90mm square with a 65mm mounting screw offset. 2. Existing mounting screws are typically 5mm to 10mm. Check local machine screw dimensions and thread style when planning the installation. Typical required length is 10mm to 20mm. Replacement machine screws should be obtained locally prior to the installation. Step 1: Remove and discard cover over existing wall plate 3. Remove plastic cover and expose RJ11 bracket and mounting screws 4. Remove mounting screws 5. Align bracket horizontal slots over 65mm offset mounting holes 6. Install mounting screws (replace with 20mm machine screws if necessary) Step 2: Install RJ11 line cable 7. Connect short RJ11 pigtail cable to internal RJ11 connector on the m2a circuit board 8. Connect other side of RJ11 pigtail cable to RJ11 connector on the RJ11 wall plate Step 3: Attach cover to the bracket 9. Use a slight angle to align the bottom connector. 10. Apply firm pressure to the top and bottom of cover to snap the connectors in place. 11. Install two (2) set screws in the pre-drilled holes in the top of the cover. Motorola, Inc. 549453-001-00-a Page 22 of 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

WallPlate Installation
Motorola, Inc.
549453-001-00-a
Page 22 of 51
Installation 2: Install over European wall plate with 65mm offset
The European style wall plate is comprised of four primary parts; the box, the modular connector, mounting bracket
for the modular connector, and the outer plastic cover.
The decorative plastic cover can be discarded and replaced
by the m2a WallPlate.
Variance from Country to Country
1.
Typical dimensions of the telco box are 70mm square; 85mm square, or 90mm square with a 65mm mounting
screw offset.
2.
Existing mounting screws are typically 5mm to 10mm.
Check local machine screw dimensions and thread
style when planning the installation.
Typical required length is 10mm to 20mm.
Replacement machine
screws should be obtained locally prior to the installation.
Step 1:
Remove and discard cover over existing wall plate
3.
Remove plastic cover and expose RJ11 bracket and mounting
screws
4. Remove mounting screws
5.
Align bracket horizontal slots over 65mm offset mounting holes
6.
Install mounting screws (replace with 20mm machine screws if
necessary)
Step 2:
Install RJ11 line cable
7.
Connect short RJ11 pigtail cable to internal RJ11
connector on the m2a circuit board
8.
Connect other side of RJ11 pigtail cable to RJ11 connector
on the RJ11 wall plate
Step 3:
Attach cover to the bracket
9.
Use a slight angle to align the bottom connector.
10. Apply firm pressure to the top and bottom of cover to
snap the connectors in place.
11. Install two (2) set screws in the pre-drilled holes in the
top of the cover.