CONFIDENTIAL ID number setting When using more than one of these displays, this function sets ID numbers so that operation of the remote control does not cause multiple monitors to operate at the same time. Example: Setting "2" Set "ADVANCED OSM" to "ON" in the main menu (1/ 2), then perform the following operations. On "ID NUMBER" of "OPTION3" menu, select "2". OPTION3 3 / 4 PREVIOUS PAGE TIMER PWR. ON MODE : LAST CONTROL LOCK : OFF IR REMOTE : ON LOOP OUT : OFF ID NUMBER : 2 VIDEO WALL NEXT PAGE SEL. ADJ. EXIT RETURN * To reset back to ALL Press the CLEAR/SEAMLESS SW button Information Ⅵ ID NUMBER settings ALL: ID NUMBER will not be set. 1 to 256: ID NUMBER will be set. Ⅵ When the ID NUMBER have been set You can also set ID NUMBER for each remote control to operate the plasma display individually. To do so, see the following explanation. To set the ID number for the remote control Example: Setting "2" Press the ID SELECT button on the remote control. The "ID SELECT" screen appears. On "ID NUMBER" of "ID SELECT" menu, select "2". ID SELECT POSITION : 1 ID NUMBER : 2 DIVIDER Set the 4-25 video wall. Example: Setting "4" On "DIVIDER" of "VIDEO WALL" menu, select "4". VIDEO WALL DIVIDER : 4 POSITION DISP. MODE : SPLIT AUTO ID : OFF IMAGE ADJUST P. ON DELAY : OFF PLE LINK : OFF REPEAT TIMER : OFF SEL. ADJ. EXIT RETURN Information Ⅵ DIVIDER settings OFF, 1: 1 Screen (Matrix display function does not work) 4: 4 Screens (2×2 video wall) 9: 9 Screens (3×3 video wall) 16: 16 Screens (4×4 video wall) 25: 25 Screens (5×5 video wall) * When you select 4-25, set the VIDEO WALL POSITION. VIDEO WALL POSITION Set the position of each display. Example: Setting "4" On "VIDEO WALL" menu, select "POSITION", then press the MENU/ENTER button. The "VIDEO WALL POSITION" screen appears. Select "NO. 4" of "POSITION NO.". VIDEO WALL POSITION POSITION NO. 4 ADJ. EXIT RETURN ADJ. EXIT RETURN * To reset back to ALL Press the CLEAR/SEAMLESS SW button Information Ⅵ VIDEO WALL POSITION settings 1 Screen: There is no need to set POSITION. 4 Screens 9 Screens Video Wall setting Use this feature to configure a 4-25 video wall. Set "ADVANCED OSM" to "ON" in the main menu (1/ 2), then perform the following operations. On "OPTION3" menu, select "VIDEO WALL", then press the MENU/ENTER button. The "VIDEO WALL" screen appears. VIDEO WALL DIVIDER : 1 POSITION DISP. MODE : SPLIT AUTO ID : OFF IMAGE ADJUST P. ON DELAY : OFF PLE LINK : OFF REPEAT TIMER : OFF SEL. ADJ. EXIT RETURN NO. 1 NO. 2 NO. 4 NO. 3 16 Screens NO. 16 NO. 17 NO. 18 NO. 19 NO. 20 NO. 21 NO. 22 NO. 23 NO. 24 NO. 25 NO. 26 NO. 27 NO. 28 NO. 29 NO. 30 NO. 31 NO. 7 NO. 8 NO. 9 NO. 10 NO. 11 NO. 12 NO. 13 NO. 14 NO. 15 25 Screens NO. 32 NO. 33 NO. 34 NO. 35 NO. 36 NO. 37 NO. 38 NO. 39 NO. 40 NO. 41 NO. 42 NO. 43 NO. 44 NO. 45 NO.46 NO. 47 NO. 48 NO. 49 NO. 50 NO. 51 NO. 52 NO. 53 NO. 54 NO. 55 NO. 56 Note: A contingency method of shutting off the electric power should be used in cases of emergency during video wall setup. E-29 4-33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

E-29
ID number setting
When using more than one of these displays, this function
sets ID numbers so that operation of the remote control
does not cause multiple monitors to operate at the same
time.
Example: Setting “2”
Set “ADVANCED OSM” to “ON” in the main menu (1/
2), then perform the following operations.
On “ID NUMBER” of “OPTION3” menu, select “2”.
OPTION3
3 / 4
EXIT
PREVIOUS PAGE
TIMER
PWR. ON MODE
CONTROL LOCK
IR REMOTE
LOOP OUT
ID NUMBER
VIDEO WALL
NEXT PAGE
:
LAST
:
OFF
:
ON
:
OFF
:
2
SEL.
RETURN
ADJ.
*
To reset back to ALL
Press the CLEAR/SEAMLESS SW button
Information
³
ID NUMBER settings
ALL:
ID NUMBER will not be set.
1 to 256:
ID NUMBER will be set.
³
When the ID NUMBER have been set
You can also set ID NUMBER for each remote control
to operate the plasma display individually. To do so,
see the following explanation.
To set the ID number for the remote control
Example: Setting “2”
Press the ID SELECT button on the remote control.
The “ID SELECT” screen appears.
On “ID NUMBER” of “ID SELECT” menu, select “2”.
ID SELECT
POSITION :
1
EXIT
:
2
RETURN
ADJ.
ID NUMBER
*
To reset back to ALL
Press the CLEAR/SEAMLESS SW button
Video Wall setting
Use this feature to configure a 4-25 video wall.
Set “ADVANCED OSM” to “ON” in the main menu (1/
2), then perform the following operations.
On “OPTION3” menu, select “VIDEO WALL”, then press
the MENU/ENTER button.
The “VIDEO WALL” screen appears.
VIDEO WALL
EXIT
DIVIDER
POSITION
DISP. MODE
AUTO ID
IMAGE ADJUST
P. ON DELAY
PLE LINK
REPEAT TIMER
:
1
:
SPLIT
:
OFF
:
OFF
:
OFF
:
OFF
SEL.
RETURN
ADJ.
Note:
A contingency method of shutting off the electric
power should be used in cases of emergency during video
wall setup.
DIVIDER
Set the 4-25 video wall.
Example: Setting “4”
On “DIVIDER” of “VIDEO WALL” menu, select “4”.
VIDEO WALL
EXIT
DIVIDER
POSITION
DISP. MODE
AUTO ID
IMAGE ADJUST
P. ON DELAY
PLE LINK
REPEAT TIMER
:
4
:
SPLIT
:
OFF
:
OFF
:
OFF
:
OFF
SEL.
RETURN
ADJ.
Information
³
DIVIDER settings
OFF, 1:
1 Screen (Matrix display function does not
work)
4:
4 Screens (2
×
2 video wall)
9:
9 Screens (3
×
3 video wall)
16:
16 Screens (4
×
4 video wall)
25:
25 Screens (5
×
5 video wall)
* When you select 4-25, set the VIDEO WALL
POSITION.
VIDEO WALL POSITION
Set the position of each display.
Example: Setting “4”
On “VIDEO WALL” menu, select “POSITION”, then press
the MENU/ENTER button.
The “VIDEO WALL POSITION” screen appears.
Select “NO. 4” of “POSITION NO.”.
VIDEO WALL POSITION
POSITION NO.
4
EXIT
RETURN
ADJ.
Information
³
VIDEO WALL POSITION settings
1 Screen:
There is no need to set POSITION.
4 Screens
9 Screens
16 Screens
25 Screens
NO. 1
NO. 2
NO. 4
NO. 3
NO. 7
NO. 8
NO. 9
NO. 10
NO. 11
NO. 12
NO. 13
NO. 14
NO. 15
NO. 16
NO. 17
NO. 18
NO. 19
NO. 20
NO. 21
NO. 22
NO. 23
NO. 24
NO. 25
NO. 26
NO. 27
NO. 28
NO. 29
NO. 30
NO. 31
NO. 32
NO. 33
NO. 34
NO. 35
NO. 36
NO. 37
NO. 38
NO. 39
NO. 40
NO. 41
NO. 42
NO. 43
NO. 44
NO. 45
NO.46
NO. 47
NO. 48
NO. 49
NO. 50
NO. 51
NO. 52
NO. 53
NO. 54
NO. 55
NO. 56