7. Power control procedure 7.1 Power status read 1) The controller requests the monitor to reply a current power status. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'6' Message STX-'0'-'1'-'D'-'6'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID from which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message Type is "Command". '0'-'6' (30h, 36h): Message length is 6 bytes. Message STX (02h): Start of Message '0'-'1'-'D'-'6': Get power status command. ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet 2) The monitor returns with the current power status. Header Message SOH-'0'-'0'-Monitor ID'B'-'1'-'2' STX-'0'-'2'-'0'-'0'-'D'-'6'-'0'-'0''0'-'0'-'0'-'4'-'0'-'0'-'0'-'1'-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller. Monitor ID: Indicate a replying Monitor ID. Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message Type is "Command reply". '1'-'2' (31h, 32h): Message length is 18 bytes. Message STX (02h):Start of Message '0'-'2' (30h, 32h): Reserved data '0'-'0' (30h, 30h): Result code 00: No Error. 01: Unsupported. 'D'-'6'(44h, 36h): Display power mode code '0'-'0' (30h, 30h): Parameter type code is "Set parameter". '0'-'0'-'0'-'4' (30h, 30h, 30h, 34h): Power mode is 4 types. '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Current power mode 0001: ON 0002: No mean 0003: power save 0004: OFF (same as IR power off) ETX (03h): End of Message Check code BCC: Block Check Code (26/47)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

(26/47)
7. Power control procedure
7.1 Power status read
1) The controller requests the monitor to reply a current power status.
Header
Message
Check
code
Delimiter
SOH-'0'-Monitor ID-
'0'-'A'-'0'-'6'
STX-'0'-'1'-'D'-'6'-ETX
BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message Type is "Command".
'0'-'6' (30h, 36h): Message length is 6 bytes.
Message
STX (02h): Start of Message
'0'-'1'-'D'-'6': Get power status command.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3
Check code
for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor returns with the current power status.
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message Type is "Command reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h):Start of Message
'0'-'2' (30h, 32h): Reserved data
'0'-'0' (30h, 30h): Result code
00: No Error.
01: Unsupported.
'D'-'6'(44h, 36h): Display power mode code
'0'-'0' (30h, 30h): Parameter type code is "Set parameter".
'0'-'0'-'0'-'4' (30h, 30h, 30h, 34h): Power mode is 4 types.
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Current power mode
<Status>
0001: ON
0002: No mean
0003: power save
0004: OFF (same as IR power off)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Header
Message
Check
code
Delimiter
SOH-'0'-'0'-Monitor ID-
'B'-'1'-'2'
STX-'0'-'2'-'0'-'0'-'D'-'6'-'0'-'0'-
'0'-'0'-'0'-'4'-'0'-'0'-'0'-'1'-ETX
BCC
CR