NEC LCD3215 External Control Guide - Page 15
Power control procedure - stand
UPC - 805736024319
View all NEC LCD3215 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
7. Power control procedure 7.1 Power status read 1) The controller requests the monitor to reply a current power status. Header SOH-'0'-'A'-'0'-'A'-'0'-'6' Message Check code STX-'0'-'1'-'D'-'6'-ETX BCC Header SOH (01h): Start Of Header '0' (30h): Reserved 'A' (41h): Monitor ID LCD3215/LCD4215 must be ASCII 'A' (41h). '0' (30h): Message sender is the controller 'A' (41h): Message Type is "Command" '0'-'6' (30h, 36h): Message length is 6 bytes Message STX (02h): Start of Message '0'-'1'-'D'-'6': Get power status command ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet. Delimiter CR 2) The monitor returns with the current power status. Header SOH-'0'-'0'-'A'-'B'-'1'-'2' Message STX-'0'-'2'-'0'-'0'-'D'-'6'-'0'-'0'-'0' -'0'-'0'-'4'-'0'-'0'-'0'-'1'-ETX Check code Delimiter BCC CR Header SOH (01h): Start Of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller 'A' (41h): Monitor ID LCD3215/LCD4215 must be ASCII 'A' (41h). 'B' (42h): Message Type is "Command reply" '1'-'2' (31h, 32h): Message length is 18 bytes Message STX(02h):Start of Message '0'-'2' (30h, 32h): Reserved data '0'-'0' (30h, 30h): Result code 00: No Error 01: Unsupported 'D'-'6'(44h, 36h): Display power mode code '0'-'0' (30h, 30h): Parameter type code is "Set parameter" '0'-'0'-'0'-'4' (30h, 30h, 30h, 34h): Power mode is 4 types '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Current power mode 0001: ON 0002: Stand-by (power save) 0003: Suspend (power save) 0004: OFF (same as IR power off) ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet (15/37)