NEC LCD3215 External Control Guide - Page 4

Header, Message, Delimiter

Page 4 highlights

3 Set parameter The controller sends this message to change a setting of the monitor. Message format of the "Set parameter" is as follows, STX OP code OP code page Set Value ETX Hi Lo Hi Lo MSB LSB  Refer to section 5.3 "Set parameter" for more details. 4 Set Parameter reply The monitor replies with this message for a confirmation of the "Set parameter message". Message format of the "Set parameter reply" is as follows, Result OP code OP code STX page Type Max value Requested setting ETX Value Hi Lo Hi Lo Hi Lo Hi Lo MSB LSB MSB LSB  Refer to section 5.4 "Set parameter reply" for more details. 5 Command "Command message" format depends on each command. Usually, this "command message" is used for some non-slider controls and some special operations, such as "Save current settings", "Get timing report", "power control", "Schedule", etc. Refer to section 5.5 "Commands message" for more details. 6 Command reply The monitor replies to a query from the controller. "Command reply message" format depends on each command. Refer to section 5.5 "Commands message" for more details. 4.5 Check code Header Message Check code Delimiter Check code is the Block Check Code (BCC) between the Header and the End of Message except SOH. SOH Reserved Destination Source Type Length STX Data | | ETX Check code 27 26 25 24 23 22 21 20 D0 D1 D2 D3 D4 D5 D6 D7 | | Dn Dn+1 P P P P P P P P (4/37)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

(4/37)
3
Set parameter
The controller sends this message to change a setting of the monitor.
Message format of the
Set parameter
is as follows,
Refer to section 5.3
Set parameter
for more details.
4
Set Parameter reply
The monitor replies with this message for a confirmation of the
Set parameter message
.
Message format of the
Set parameter reply
is as follows,
Refer to section 5.4
Set parameter reply
for more details.
5
Command
Command message
format depends on each command.
Usually, this
command message
is used for some non-slider controls and some special operations,
such as
Save current settings
,
Get timing report
,
power control
,
Schedule
, etc. Refer to
section 5.5
Commands message
for more details.
6
Command reply
The monitor replies to a query from the controller.
Command reply message
format depends on each command.
Refer to section 5.5
Commands message
for more details.
4.5 Check code
Check code is the Block Check Code (BCC) between the Header and the End of Message except SOH.
OP code
page
OP code
Set Value
STX
Hi Lo
Hi
Lo
MSB
LSB
ETX
Result
OP code
page
OP code
Type
Max value
Requested setting
Value
ETX
STX
Hi
Lo
Hi
Lo
Hi
Lo
Hi
Lo
MSB
LSB
MSB
LSB
Header
Message
Check code
Delimiter
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
SOH
D
0
Reserved
D
1
Destination
D
2
Source
D
3
Type
D
4
Length
D
5
STX
D
6
Data
D
7
|
|
|
|
ETX
D
n
Check code
D
n+1
P
P
P
P
P
P
P
P