NEC LCD3215 External Control Guide - Page 4
Header, Message, Delimiter
UPC - 805736024319
View all NEC LCD3215 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
3 Set parameter The controller sends this message to change a setting of the monitor. Message format of the "Set parameter" is as follows, STX OP code OP code page Set Value ETX Hi Lo Hi Lo MSB LSB Refer to section 5.3 "Set parameter" for more details. 4 Set Parameter reply The monitor replies with this message for a confirmation of the "Set parameter message". Message format of the "Set parameter reply" is as follows, Result OP code OP code STX page Type Max value Requested setting ETX Value Hi Lo Hi Lo Hi Lo Hi Lo MSB LSB MSB LSB Refer to section 5.4 "Set parameter reply" for more details. 5 Command "Command message" format depends on each command. Usually, this "command message" is used for some non-slider controls and some special operations, such as "Save current settings", "Get timing report", "power control", "Schedule", etc. Refer to section 5.5 "Commands message" for more details. 6 Command reply The monitor replies to a query from the controller. "Command reply message" format depends on each command. Refer to section 5.5 "Commands message" for more details. 4.5 Check code Header Message Check code Delimiter Check code is the Block Check Code (BCC) between the Header and the End of Message except SOH. SOH Reserved Destination Source Type Length STX Data | | ETX Check code 27 26 25 24 23 22 21 20 D0 D1 D2 D3 D4 D5 D6 D7 | | Dn Dn+1 P P P P P P P P (4/37)