NEC NP-V260X RS232 codes- Projectors - Page 14

NP40/NP50/NP60/NP41/NP61/NP62/NP43/NP64 and P350X/350W/420X, the term RGB connector has been - case

Page 14 highlights

In case of VT series In case of NP600 series In case of NP610 series In case of NP2200 series In case of M300 series In case of P420 series In case of GT series In case of HT series In case of WT series In case of HT10 series In case of LT180 series In case of LT30 series In case of NP60 series In case of NP4000, 4100 series In case of U300 series In case of NP905/NP901W/VT800 40H 40H 40H 40H 40H 40H 50H 60H 70H D0H D0H D0H D0H 80H 80H 90H (*3) Checksum: "CKS" inscription This is the value of the lower 8 bits of the results calculated in byte units from all of the data up to the immediately preceding data. Example: 20H 81H 01H 60H 01H 00H 03H CKS (*4) Response error number This is the value of the error number at the time of an error. See "NAK" of "6-2. Data portion of response". (*5) Term "RGB" and "COMPUTER" On the HT1100, VT770, LT245/ LT265/ LT280/ LT380, NP1000/NP2000, NP1150/NP2150/NP3150/NP3151W, NP1250/NP2250/NP3250/NP3250W, NP1200/NP2200, NP4000/NP4001, NP4100/NP4100W, NP905/NP901W/VT800, LT25/LT30/LT35, VT48/VT480/VT580, VT49/VT490/VT590/VT595/VT695/VT700, NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S, NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S, NP40/NP50/NP60/NP41/NP61/NP62/NP43/NP64 and P350X/350W/420X, the term "RGB connector" has been changed to "COMPUTER". (*6) Term "DVI" and "COMPUTER" On the LT380, NP1000/NP2000, NP1150/NP2150/NP3150/NP3151W, NP1250/NP2250/NP3250/NP3250W, NP1200/NP2200, NP4000/NP4001, NP4100/NP4100W, NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S, NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S and VT595/VT695/VT700, the term "DVI connector" has been changed to "COMPUTER". 006. RUNNING SENSE Function: This command acquires the operation mode of the projector. Command: 00H 81H 00H 00H 00H 81H Response: At the time of a success 20H 81H 01H xxH 01H DATA01 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Status of operation Bit 7: Power On/Off processing

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

In case of VT series
40H
In case of NP600 series
40H
In case of NP610 series
40H
In case of NP2200 series
40H
In case of M300 series
40H
In case of P420 series
40H
In case of GT series
50H
In case of HT series
60H
In case of WT series
70H
In case of HT10 series
D0H
In case of LT180 series
D0H
In case of LT30 series
D0H
In case of NP60 series
D0H
In case of NP4000, 4100 series
80H
In case of U300 series
80H
In case of NP905/NP901W/VT800
90H
(*3) Checksum: "CKS" inscription
This is the value of the lower 8 bits of the results calculated in byte units from all of the data up to the immediately
preceding data.
Example:
20H
81H
01H
60H
01H
00H
03H
+
+
+
+
+
+
= CKS
(*4) Response error number
This is the value of the error number at the time of an error.
See "NAK" of "6-2. Data portion of response".
(*5) Term
RGB” and “COMPUTER”
On the HT1100, VT770, LT245/ LT265/ LT280/ LT380, NP1000/NP2000, NP1150/NP2150/NP3150/NP3151W,
NP1250/NP2250/NP3250/NP3250W, NP1200/NP2200, NP4000/NP4001, NP4100/NP4100W,
NP905/NP901W/VT800, LT25/LT30/LT35, VT48/VT480/VT580, VT49/VT490/VT590/VT595/VT695/VT700,
NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S,
NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S,
NP40/NP50/NP60/NP41/NP61/NP62/NP43/NP64 and P350X/350W/420X, the term "RGB connector" has been
changed to "COMPUTER".
(*6) Term “DVI” and “COMPUTER
On the LT380, NP1000/NP2000, NP1150/NP2150/NP3150/NP3151W, NP1250/NP2250/NP3250/NP3250W,
NP1200/NP2200, NP4000/NP4001, NP4100/NP4100W,
NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S,
NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S and VT595/VT695/VT700, the term "DVI
connector" has been changed to "COMPUTER".
006. RUNNING SENSE
**********************************************************************
Function:
This command acquires the operation mode of the projector.
Command:
00H
81H
00H
00H
00H
81H
Response: At the time of a success
20H
81H
01H
xxH
01H
DATA01
CKS
(*1)
(*2)
(*3)
Data Portion Contents
-------------------------------------------------------------------
DATA01
Status of operation
Bit 7: Power On/Off processing