NEC NP-V260X RS232 codes- Projectors - Page 31

Punch in DATA06 DATA05 DATA04 DATA03 00057E40

Page 31 highlights

to appear (in terms of Normal mode values) 0AH : Remaining time until lamp warning message starts to appear (in terms of Eco mode values) 10H : Remaining time until inhibition of lamp usage (in terms of specified values) 11H : Remaining time until inhibition of lamp usage (in terms of Normal mode values) 12H : Remaining time until inhibition of lamp usage (in terms of Eco mode values) Response: At the time of a success 23H 96H 01H xxH 06H DATA01 .. DATA06 CKS (*1) (*2) (*3) Data Portion Contents DATA01 same values as DATA01 of the command DATA02 same values as DATA02 of the command DATA03 .. 06 Acquired information Response: At the time of a failure A3H 96H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: * In case of acquiring lamp's use of hours 03H 96H 00H 00H 02H 00H 01H 9CH Example of acquisition DATA03 DATA04 DATA05 DATA06: lamp's use of hours 50H 46H 00H 00H: 18000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA06 DATA05 DATA04 DATA03 (00004650) 3) Change from HEX to Decimal - value will change to 18000 seconds Lamp's use of hours = 18000/3600 = 5 hours * In case of acquiring the remaining time until lamp warning message starts to appear (in terms of specified values) 03H 96H 00H 00H 02H 00H 08H A3H Example of acquisition DATA03 DATA04 DATA05 DATA06: Remaining time 40H 7EH 05H 00H: 360000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA06 DATA05 DATA04 DATA03 (00057E40) 3) Change from HEX to Decimal - value will change to 360000 seconds Remaining time until lamp warning message starts to appear = 360000/ 3600= 100 hours (!) Lamp Hour Meter This is the timer for normal lamp mode conversion. (!!) Lamp usage time This is the lamp total usage. It is displayed in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is not supported.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

to appear (in terms of Normal mode values)
0AH :
Remaining time until lamp warning message starts
to appear (in terms of Eco mode values)
10H :
Remaining time until inhibition of lamp usage
(in terms of specified values)
11H :
Remaining time until inhibition of lamp usage
(in terms of Normal mode values)
12H :
Remaining time until inhibition of lamp usage
(in terms of Eco mode values)
Response: At the time of a success
23H
96H
01H
xxH
06H
DATA01 .. DATA06
CKS
(*1)
(*2)
(*3)
Data Portion Contents
-------------------------------------------------------------------
DATA01
same values as DATA01 of the command
DATA02
same values as DATA02 of the command
DATA03 .. 06
Acquired information
Response: At the time of a failure
A3H
96H
01H
xxH
02H
DATA01
DATA02
CKS
(*1)
(*2)
(*4)
(*3)
Supplement:
* In case of acquiring lamp's use of hours
03H
96H
00H
00H
02H
00H
01H
9CH
Example of acquisition
DATA03
DATA04
DATA05
DATA06:
lamp's use of hours
50H
46H
00H
00H:
18000 seconds
Calculator Procedure
1) Set calculator to HEX
2) Punch in DATA06 DATA05 DATA04 DATA03 (00004650)
3) Change from HEX to Decimal - value will change to 18000 seconds
Lamp's use of hours = 18000/3600 = 5 hours
* In case of acquiring the remaining time until lamp warning message starts to appear (in terms of specified
values)
03H
96H
00H
00H
02H
00H
08H
A3H
Example of acquisition
DATA03
DATA04
DATA05
DATA06:
Remaining time
40H
7EH
05H
00H:
360000 seconds
Calculator Procedure
1) Set calculator to HEX
2) Punch in DATA06 DATA05 DATA04 DATA03 (00057E40)
3) Change from HEX to Decimal - value will change to 360000 seconds
Remaining time until lamp warning message starts to appear
= 360000/ 3600= 100 hours
(!) Lamp Hour Meter
This is the timer for normal lamp mode conversion.
(!!) Lamp usage time
This is the lamp total usage. It is displayed in the projector's menu.
(!!!) NP4000/4001, NP4100/4100W : This function is not supported.