NEC VT595 NP115 : RS232 codes- Projectors - Page 38
H : Adjustment impossible
UPC - 050927253591
View all NEC VT595 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Function: This command acquires the adjustment values. Command: 03H 04H 00H 00H 03H DATA01 .. DATA03 CKS (*3) Data Portion Contents DATA01 .. 02 Acquirement items (!) DATA03 00H fixed Response: At the time of a success 23H 04H 01H xxH 0DH DATA01 .. DATA13 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Adjustment status 00H : Displaying impossible 01H : Adjustment impossible 02H : Adjustment possible FFH : Selected gain is not available. DATA02 Maximum adjustment value (Lower ranking 8 bits) DATA03 Maximum adjustment value (Upper ranking 8 bits) DATA04 Minimum adjustment value (Lower ranking 8 bits) DATA05 Minimum adjustment value (Upper ranking 8 bits) DATA06 Default adjustment value (Lower ranking 8 bits) DATA07 Default adjustment value (Upper ranking 8 bits) DATA08 Current value (Lower ranking 8 bits) DATA09 Current value (Upper ranking 8 bits) DATA10 .. 13 Reserved Response: At the time of a failure A3H 04H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3)