Netgear M4100-12GF Hardware Installation Guide

Netgear M4100-12GF Manual

Netgear M4100-12GF manual content summary:

  • Netgear M4100-12GF | Hardware Installation Guide - Page 1
    Managed Switch Hardware Installation Guide Models: M4100 Series 350 East Plumeria Drive San Jose, CA 95134 USA November 2013 202-11217-02 v1.0
  • Netgear M4100-12GF | Hardware Installation Guide - Page 2
    NETGEAR Managed Switch Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label of your product and use it to register your product at https://my.netgear.com. You must register your product before you can use NETGEAR telephone support.
  • Netgear M4100-12GF | Hardware Installation Guide - Page 3
    16 Install the M4100-D12G or M4100-D10-PoE Using Magnets 19 Check the Installation 20 Connect to Power and Check the LEDs 20 SFP Modules 21 Connect Equipment to the Switch 22 RJ-45 Ports 22 Connect a Console to the Switch 22 Chapter 3 Troubleshooting Troubleshooting Chart 24 Additional
  • Netgear M4100-12GF | Hardware Installation Guide - Page 4
    M4100-24G-POE+ M4100-12G-POE+ This guide describes hardware installation and basic troubleshooting for these managed switches. These switches can be freestanding, wall mounted, or rack mounted in a wiring closet or an equipment room. For information about features for each product, visit the NETGEAR
  • Netgear M4100-12GF | Hardware Installation Guide - Page 5
    NETGEAR Managed Switch LEDs USB port Reset button Figure 1. M4100-26G front panel RJ-45 ports SFP ports Combo Ports Power Fan RPS Reset USB RJ45 SPD/Link/ACT mode: Green = 1G Yellow = 10/100M Blink = ACT LEDs USB port Reset button Figure 2. M4100-50G front panel RJ-45 ports SFP SPD/Link/
  • Netgear M4100-12GF | Hardware Installation Guide - Page 6
    NETGEAR Managed Switch LEDs USB port Reset button Figure 5. M4100-26G-POE front panel POE ports RJ-45 ports SFP ports LEDs USB port Reset button POE ports Figure 6. M4100-50G-POE+ front panel RJ45 ports SFP ports LEDs USB port Reset button POE ports Figure 7. M4100-D10-POE Front Panel
  • Netgear M4100-12GF | Hardware Installation Guide - Page 7
    NETGEAR Managed Switch Power Fan PD MaxPoE Reset USB PoE (Max 30W per port): Off = No PD Green = PoE Powered Yellow = PoE Fault PoE SPD/Link/ACT RJ45 SPD/Link/ACT mode: Green = 1G Yellow = 10/100M Blink = ACT LEDs USB port Reset button Figure 9. M4100-24G-POE+ front panel SPD/Link/ACT M4100-
  • Netgear M4100-12GF | Hardware Installation Guide - Page 8
    NETGEAR Managed Switch Table 1. LED descriptions LED Power Fan RPS PD Max PoE SPD/Link/ACT (RJ-45 port) PoE Description Solid green: Internal power supply operating normally and supplying power to the switch. Solid yellow: The system is in boot-up stage. Blinking yellow: Power module is present
  • Netgear M4100-12GF | Hardware Installation Guide - Page 9
    NETGEAR Managed Switch Table 1. LED descriptions (Continued) LED Link/ACT (RJ45 port) SPD ( for M4100-26G, 50G, 26-POE, 26G-POE, 50G-POE+, 50-POE, D12-PoE, and D12G), a redundant power supply connector (only for M4100-26G, 50G, 26-POE, 26G-POE, 50G-POE+, 50-POE, 12GF, 24G-POE+, and 12G-POE+), and
  • Netgear M4100-12GF | Hardware Installation Guide - Page 10
    NETGEAR Managed Switch Console switch Console ports Lock Power adapter connector Figure 14. M4100-D10-POE and M4100-D12G rear panels Console port RPS Lock power supply connector Figure 15. M4100-12GF, 24G-POE+, 12G-POE+ rear panel AC power connector Lock Console port Figure 16. M4100-
  • Netgear M4100-12GF | Hardware Installation Guide - Page 11
    NETGEAR Managed Switch - Opening or removing covers that are marked with the triangular symbol with a lightning bolt might expose you to electrical shock. Only a trained service technician should service components inside these compartments. • If any of the following conditions occur, unplug the
  • Netgear M4100-12GF | Hardware Installation Guide - Page 12
    NETGEAR Managed Switch • Observe extension cable and power strip ratings. Make sure that the total ampere rating of all products plugged into the extension cable or power strip
  • Netgear M4100-12GF | Hardware Installation Guide - Page 13
    to access them: - ProSafe Managed Switch Command-Line Interface (CLI) User Manual - ProSafe M4100 and M7100 Managed Switches Software Administration Manual - ProSafe M4100 Managed Switch Installation Guide - This hardware installation guide • ProSafe NMS200 Network Management System 30-day trial
  • Netgear M4100-12GF | Hardware Installation Guide - Page 14
    NETGEAR Managed Switch You can also take the following steps to prevent damage from electrostatic discharge Check the contents of the boxes to make sure that all items are present before installing the switch. 1. Place the container on a clean flat surface and cut all straps securing the container.
  • Netgear M4100-12GF | Hardware Installation Guide - Page 15
    NETGEAR Managed Switch For more information, see Connect to Power and Check the LEDs on page 20. Select a Location The switch can be mounted in a standard 19-inch (48.26-centimeter) rack, wall mounted, or left freestanding (placed on a tabletop). The site where you install the switch might
  • Netgear M4100-12GF | Hardware Installation Guide - Page 16
    NETGEAR Managed Switch Install the Switch You can install the switch on a flat surface or in a standard 19-inch rack. Install the Switch on a Flat Surface The switch ships with four self-adhesive rubber footpads. Stick one rubber footpad on each of the four concave spaces on the bottom of the switch
  • Netgear M4100-12GF | Hardware Installation Guide - Page 17
    NETGEAR Managed Switch 2. Use the provided Phillips head screws to fasten the brackets to the sides of the switch. M4100-24G-POE+ Mounting bracket 3. Tighten the screws with a No. 1 Phillips screwdriver to secure each bracket. 4. Align the bracket and rack holes. Use two pan-head screws with
  • Netgear M4100-12GF | Hardware Installation Guide - Page 18
    NETGEAR Managed Switch Install the Switch on a Wall (M4100-D12G, M4100-D10-PoE, and M4100-D12G-POE+ Only) If you install the switch on a wall in the vertical position, be sure to orient the switch as shown in the following figure. The switch should be mounted so that the ports face up or down. Do
  • Netgear M4100-12GF | Hardware Installation Guide - Page 19
    NETGEAR Managed Switch Install the M4100-D12G or M4100-D10-PoE Using Magnets If you use the magnets (included) to install the M4100-D12G or M4100-D10-PoE switch to a vertical metal surface, the maximum height above the floor is 75 centimeters (29.5 inches). Be sure to orient the switch as shown in
  • Netgear M4100-12GF | Hardware Installation Guide - Page 20
    NETGEAR Managed Switch Check the M4100-DG12 or M4100-D10-PoE) or the AC power cord to the rear of the switch, and the other end to a grounded three-pronged AC outlet. Note: The M4100-26G, 50G, 26-PoE, 26G-PoE, 50-PoE+, 50G-PoE, 12GF, 24G-POE+, 12G-POE+ can also obtain power from an RPS. Supported
  • Netgear M4100-12GF | Hardware Installation Guide - Page 21
    NETGEAR Managed Switch • If the POST fails, the Power LED blinks yellow. Note: If the PD LED on the front panel of the M4100-D12G and M4100-D12G-POE+ blinks green, port 1 is connected to a IEEE802.3af PoE device. Check the PoE device specification to make sure that it supports IEEE802.3at. If the
  • Netgear M4100-12GF | Hardware Installation Guide - Page 22
    NETGEAR Managed Switch Connect Equipment to the Switch You can connect devices, a Gigabit Ethernet module, and/or a console to the switch. RJ-45 Ports The switch uses Auto Uplink technology, which enables you to attach devices using either straight-through or crossover cables. Use a Category 5 (Cat
  • Netgear M4100-12GF | Hardware Installation Guide - Page 23
    NETGEAR Managed Switch Guide: Explains basic setup and configuration (provided as both a print document and in PDF format on the Resource CD). • ProSafe Managed Switch Command-Line Interface (CLI) User Manual: Gives detailed examples of how to use the CLI. • ProSafe M4100 and M7100 Managed Switches
  • Netgear M4100-12GF | Hardware Installation Guide - Page 24
    The following table lists symptoms, causes, and solutions to possible problems. Table 3. Troubleshooting chart Problem Cause Solution Power LED is off. No power is received. Check the power cord connections for the switch at the switch and the connected device. Make sure that all cables used
  • Netgear M4100-12GF | Hardware Installation Guide - Page 25
    NETGEAR Managed Switch Additional Troubleshooting Suggestions If the suggestions in Table 3 do not resolve your problem, refer to the troubleshooting supports autonegotiation. If the device does not support autonegotiation, the switch determines only the speed correctly and the duplex mode defaults
  • Netgear M4100-12GF | Hardware Installation Guide - Page 26
    A. Technical Specifications A Table 4. M4100-26G, 50G, 26G-POE, 50G-POE+, and D12G Gigabit switch physical specifications Specification Interface (Auto Uplink on all RJ-45 ports) M4100-26G M4100-50G M4100-26G-POE M4100-50G-POE+ M4100-D12G (GSM7224v2h2) (GSM7248v2h2) (GSM7226LP) (GSM7248P) (
  • Netgear M4100-12GF | Hardware Installation Guide - Page 27
    NETGEAR Managed Switch Table 5. M4100-24G-POE+, D12G-POE+, 12G-POE+, 12GF Gigabit switch physical specification Specification Interface (Auto AC, 50-60 Hz) M4100-24G-POE+ (GSM7224P) 24 RJ-45 ports for 10/100/1000 Mbps 4 SFP ports for 100/1000 Mbps 24 IEEE802.3at PoE ports 1 USB Type A connector
  • Netgear M4100-12GF | Hardware Installation Guide - Page 28
    NETGEAR Managed Switch Table 6. Fast Ethernet switches physical specifications Fast Ethernet Switches M4100-26-POE (FSM7226P) M4100-50-POE (FSM7250P) M4100-D10-POE (FSM5210P) Interface (AutoUplink on all RJ-45 ports) 24 RJ-45 ports for 10/100 Mbps 48 RJ-45 ports for 10/100 Mbps 8 RJ-
  • Netgear M4100-12GF | Hardware Installation Guide - Page 29
    NETGEAR Managed Switch Table 7. Technical specifications Feature Description IEEE Network Protocol and Standards v2 snooping support • MLD snooping • DHCP L2 relay • UDP relay • SNTP • SNMP v1/v2/v3 • LLDP • ISDP Layer 3 services • Static routing QoS • DiffServ QoS System Service • DHCP,
  • Netgear M4100-12GF | Hardware Installation Guide - Page 30
    NETGEAR Managed Switch Table 7. Technical specifications (Continued) Feature Description Security • Radius • TACACS+ • 802.1x • MAC filter • Port security • Protected port • Private group • Storm control • DHCP snooping • IP source guard • Dynamic ARP inspection • MAC ACL (inbound) • IP ACL (
  • Netgear M4100-12GF | Hardware Installation Guide - Page 31
    B Table 8. M4100 Series switch default settings Feature Default Setting Port speed Autonegotiation Port duplex Autonegotiation Flow control (half duplex) Enabled Flow control (full duplex) Disabled Broadcast storm control Enabled Gigabit port type Auto detect Management IP configuration
  • Netgear M4100-12GF | Hardware Installation Guide - Page 32
    NETGEAR Managed Switch Table 8. M4100 Series switch default settings (Continued) Feature GMRP IP routing MAC address aging SNMP community DHCP Server VLAN Ingress filtering IP multicast filtering 802.1x Port Security Auto Install LLDP LLDP-MED ISDP Default Setting Disabled Disabled 300 seconds
  • Netgear M4100-12GF | Hardware Installation Guide - Page 33
    certain restrictions. Please refer to the notes in the operating instructions. Federal Office for Telecommunications Approvals has been notified of the of Conformance This is to certify that the NETGEAR ProSafe® 4100 series managed switches are shielded against the generation of radio interference
  • Netgear M4100-12GF | Hardware Installation Guide - Page 34
    EN 55 022 and EN 55 024 Statements This is to certify that the NETGEAR ProSafe® 4100 series managed switches are shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

350 East Plumeria Drive
San Jose, CA 95134
USA
November 2013
202-11217-02
v1.0
Managed Switch
Hardware Installation Guide
Models:
M4100 Series