Oki LP470s LP440, LP441, LP470, LP480 Printer Configuration Manual (English) - Page 15

Protocol setting

Page 15 highlights

Printer configuration tool 6.4 Protocol setting Before starting communication with the printer, the printer setting tool needs to be set for enabling communication with the printer. 1. Select "Protocol (P)" in "Tool settings(T)" menu.  Fig. 6-4-1 Tool setting (Protocol setting) selection screen 2. Change setting value, and click "Apply". Fig. 6-4-2 Tool setting (Protocol setting) screen Table6-4-2 Tool item setting (Protocol setting) list Item CRC check setting Setting range ON, OFF Control code setting ON, OFF Protocol code 00 - FF HEX setting Restrictions Only effective when printer uses wireless LAN or Bluetooth is active. The value being used in other protocol code cannot be set. When other control code and command, code included in printer data are specified as protocol code, printer operation is not warranted. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

Printer configuration tool
13
6.4
Protocol setting
Before starting communication with the printer, the printer setting tool needs to be set for
enabling communication with the printer.
1. Select "Protocol (P)" in "Tool settings(T)" menu.
Fig. 6-4-1 Tool setting (Protocol setting) selection screen
2. Change setting value, and click “Apply”.
Fig. 6-4-2 Tool setting (Protocol setting) screen
Table6-4-2 Tool item setting (Protocol setting) list
Item
Setting range
Restrictions
CRC check setting
ON, OFF
Only effective when printer uses wireless LAN or
Bluetooth is active.
Control code setting
ON, OFF
Protocol
code
setting
00 - FF HEX
The value being used in other protocol code cannot
be set. When other control code and command,
code included in printer data are specified as
protocol code, printer operation is not warranted.