Oregon Scientific RGR126 User Manual - Page 12

Technical Specifications, Notices - user

Page 12 highlights

EN TECHNICAL SPECIFICATIONS TYPE DESCRIPTION Main Unit Dimensions L x W x H 3.54 x 0.98 x 5.59 inches (90 x 25 x 142 mm) Weight (without battery) 0.38 lbs (173 g) Main unit Display rainfall range (total) 0 - 999.99 inch (0 - 25,400 mm) Display rainfall range 0 - 99.99 inch (0 - 2,540 mm) (history / daily) Rainfall resolution 0.04 inch (1 mm) Operating range 23°F to 122°F (-5°C to +50°C) Temperature resolution 0.2°F to (0.1°C) Remote Rain Gauge (PCR122) Operating range 33.8° F to 140.0°F (1.0° C to 60.0°C) Weight 0.57 lbs (260 g) Remote Thermo Sensor (THN122N) Proposed operating range -22° F to 140°F (-30° C to 60°C) Power Main unit 2 x UM-3 / AA 1.5V batteries Rain gauge 2 x UM-3 / AA 1.5V batteries Remote thermo sensor 2 x UM-4 / AAA 1.5V batteries General RF Transmission Frequency 433 MHz RF Transmission Range Rain gauge - 328 feet (100 meters) Remote thermo sensor - 98 feet (30 meters) Temperature sensing cycle Around 78 seconds Rainfall sensing cycle Around 94 seconds NOTE It is recommended that you use alkaline batteries with this product for longer performance or lithium batteries in temperatures below freezing. NOTE Design and specifications are subject to change without notice. NOTICES STATEMENT OF RESPONSIBILITY Oregon Scientific will not be held liable for any bodily injury, death, property damages, or any other claims of whatever nature resulting from the misuse or negligence of the product, whether intentional or unintentional. Oregon Scientific will not be responsible for any deviations in the usage of the device from those specified in the user instructions or any approved alternations or repairs of the product. 12 RGR126(R13)-4(final) 12 4/6/05, 5:46 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

EN
12
TECHNICAL SPECIFICATIONS
TYPE
DESCRIPTION
Main Unit Dimensions
L x W x H
3.54 x 0.98 x 5.59 inches
(90 x 25 x 142 mm)
Weight (without battery)
0.38 lbs (173 g)
Main unit
Display rainfall range (total)
0 - 999.99 inch (0 - 25,400 mm)
Display rainfall range
0 - 99.99 inch (0 - 2,540 mm)
(history / daily)
Rainfall resolution
0.04 inch (1 mm)
Operating range
23
°
F to 122
°
F
(-5
°
C to
+50
°
C)
Temperature resolution
0.2
°
F to (0.1
°
C)
Remote Rain Gauge (PCR122)
Operating range
33.8
°
F to 140.0
°
F
(1.0
°
C to 60.0
°
C)
Weight
0.57 lbs (260 g)
Remote Thermo Sensor (THN122N)
Proposed operating range
-22
°
F to 140
°
F
(-30
°
C to 60
°
C)
Power
Main unit
2 x UM-3 / AA 1.5V batteries
Rain gauge
2 x UM-3 / AA 1.5V batteries
Remote thermo sensor
2 x UM-4 / AAA 1.5V batteries
General
RF Transmission Frequency
433 MHz
RF Transmission Range
Rain gauge - 328 feet
(100 meters)
Remote thermo sensor - 98 feet
(30 meters)
Temperature sensing cycle
Around 78 seconds
Rainfall sensing cycle
Around 94 seconds
NOTE
It is recommended that you use alkaline
batteries with this product for longer performance or
lithium batteries in temperatures below freezing.
NOTE
Design and specifications are subject to change
without notice.
NOTICES
STATEMENT OF RESPONSIBILITY
Oregon Scientific will not be held liable for any bodily
injury, death, property damages, or any other claims
of whatever nature resulting from the misuse or
negligence of the product, whether intentional or
unintentional.
Oregon Scientific will not be responsible for any
deviations in the usage of the device from those
specified in the user instructions or any approved
alternations or repairs of the product.
RGR126(R13)-4(final)
4/6/05, 5:46 PM