Palsonic pw418sfzr Instruction Manual - Page 13
Press B
View all Palsonic pw418sfzr manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
●High temp. alert In refrigerator mode, if the inside temperature is over 59F(15℃) for 36 hours, then the high temperature alert is activated with the blue point blink and buzzing for 10s,and it will buzz for 10s every 30 minutes. If the temperature reach below 54 F(12℃), the High Temperature Alert will exit. Or press any button to cancel this alert. In freezer mode, if the inside temperature is over 18 F(-8 ℃) for 36 hours, then the high temperature alert is activated with the blue point blink and buzzing for 10s,and it will buzz for 10s every 30 minutes. If the temperature reach below 10 F(-12℃), the High Temperature Alert will exit. Or press any button to cancel this alert. ●Lock Press B for 3s, enter into lock status, icon is on with a beep.Then press it for another 3s to unlock it, icon is off with a beep. ●Temp Press to drop the temperature. Press to rise the Temperature. ●Reset Press B and at the same time for 3s until a beep for mainboard reset. Then all the variables of mainboard will be initialized (except the variables stored in the EEPROM). The display will be fully lighted for 3s just like the freezer is powered on for the first time. While resetting, if the compressor is running, it will pause for 5 minutes then run again. Please contact the after-sales Service Department of the Company or professionals to deal with the faults. Fault Code E2 E5 E6 E7 Fault Description Temperature sensor failure of freezing chamber Failure of defrosting sensor in freezing chamber Communication error Failure of ambient temperature sensor 11