●High temp. alert In refrigerator mode, if the inside temperature is over 59F(15℃) for 36 hours, then the high temperature alert is activated with the blue point blink and buzzing for 10s,and it will buzz for 10s every 30 minutes. If the temperature reach below 54 F(12℃), the High Temperature Alert will exit. Or press any button to cancel this alert. In freezer mode, if the inside temperature is over 18 F(-8 ℃) for 36 hours, then the high temperature alert is activated with the blue point blink and buzzing for 10s,and it will buzz for 10s every 30 minutes. If the temperature reach below 10 F(-12℃), the High Temperature Alert will exit. Or press any button to cancel this alert. ●Lock Press B for 3s, enter into lock status, icon is on with a beep.Then press it for another 3s to unlock it, icon is off with a beep. ●Temp Press to drop the temperature. Press to rise the Temperature. ●Reset Press B and at the same time for 3s until a beep for mainboard reset. Then all the variables of mainboard will be initialized (except the variables stored in the EEPROM). The display will be fully lighted for 3s just like the freezer is powered on for the first time. While resetting, if the compressor is running, it will pause for 5 minutes then run again. Please contact the after-sales Service Department of the Company or professionals to deal with the faults. Fault Code E2 E5 E6 E7 Fault Description Temperature sensor failure of freezing chamber Failure of defrosting sensor in freezing chamber Communication error Failure of ambient temperature sensor 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

11
E6
E2
E5
Fault Code
Fault Description
Please contact the after-sales Service Department of the Company or professionals to deal
with the faults.
Lock
Press B for 3s, enter into lock status, icon
is on with a beep.Then press it for another 3s to
unlock it, icon
is off with a beep.
Temp
Press
to drop the temperature. Press
to rise the Temperature.
Reset
Press B and
at the same time for 3s until a beep for mainboard reset. Then all the variables
of mainboard will be initialized (except the variables stored in the EEPROM). The display
will be fully lighted for 3s just like the freezer is powered on for the first time. While
resetting, if the compressor is running, it will pause for 5 minutes then run again.
High temp. alert
In refrigerator mode, if the inside temperature is over 59F(15
)
for 36 hours, then the
high temperature alert is activated with the blue point
blink and buzzing for 10s,and it
will buzz for 10s every 30 minutes.
If the temperature reach below
54 F(12
℃)
, the High Temperature Alert will exit.
Or press any button to cancel this alert.
In freezer mode, if the inside temperature is over 18 F(-8
℃)
for 36 hours, then the
high temperature alert is activated with the blue point
blink and buzzing for 10s,and it
will buzz for 10s every 30 minutes.
If the temperature reach below 10 F(-12
℃)
, the High Temperature Alert will exit.
Or press any button to cancel this alert.
E7
Communication error
Failure of ambient temperature
Temperature sensor failure
Failure of defrosting sensor in
of freezing chamber
sensor
freezing chamber