Panasonic ACC-195674 ECOi VRF Systems Catalog - Page 14

Mf 2 Series, Ecoi Ex

Page 14 highlights

ECOi EX™ Series MF 2 SERIES ECOi EX™ 3-WAY VRF HEAT RECOVERY Panasonic ECOi Heat Recovery series offers the ability to heat and cool different zones simultaneously. Offering all the features of our standard heat pump series, the 3-Way solution can offer even higher energy savings for the building owner. MODEL NAME Consisted of U-72MF2U9 U-72MF2U9 U-96MF2U9 U-96MF2U9 U-120MF2U9 U-120MF2U9 U-144MF2U9 U-144MF2U9 WU-168MF2U9 U-72MF2U9 +U-96MF2U9 Appearance Nominal Tons Performance test condition Power supply Cooling capacity Heating capacity Rating Standard AHRI 1230 SCHE Electrical ratings Outdoor unit only Indoor unit Cooling High heating 47°F Low heating 17°F Capacity EER IEER Capacity COP Capacity COP Voltage Ducted cooling Ducted heating Non-ducted cooling Non-ducted heating Starting current Running current Power input Power factor Running current Power input Power factor Running current Power input Power factor Running current Power input Power factor Compressor type/quantity Air flow rate External static pressure Refrigerant amount at shipment*2 Btu/h kW Btu/h kW Btu/h Btu/h Btu/h V A kW % A kW % A kW % A kW % A CFM Pa (in. WC) lbs Dimensions H x W x D inch Net weight lbs Ambient temperature operating range Gas inch Diameter Liquid inch Balance inch Piping Discharge inch Connecting method Max total pipe length Ft Elevation difference (OD upper/ OD lower) Ft Operation sound (Normal/Quiet mode) dB Maximum allowable indoor unit connection 6 8 72,000 21.1 81,000 23.7 69,000 | 69,000 12.7 | 13.3 22.3 | 28.5 77,000 | 77,000 3.70 | 3.90 56,000 | 56,000 2.66 | 2.56 27.6 | 30.2 14.4 / 13.2 4.89 / 4.89 94 / 93 16.4 / 15.0 5.62 / 5.62 95 / 94 14.0 / 12.8 4.74 / 4.74 94 / 93 15.9 / 14.5 5.43 / 5.43 95 / 94 96,000 28.1 108,000 31.6 92,000 | 90,000 11.1 | 10.8 23.2 | 25.6 103,000 | 103,000 3.32 | 3.39 70,000 | 62,000 2.44 | 2.38 29.8 | 28.4 22.0 / 20.1 7.46 / 7.46 94 / 93 24.7 / 22.5 8.35 / 8.35 94 / 93 23.0 / 21.0 7.78 / 7.78 94 / 93 25.0 / 22.9 8.47 / 8.47 94 / 93 Inverter driven Rotary×1 7,000 8,100 R410A / 18.3 R410A / 18.3 10 AHRI Standard 1230 3 208/230V 60Hz 120,000 35.2 135,000 39.6 Ducted | Non-ducted 114,000 | 114,000 11.7 | 11.7 22.4 | 27.4 129,000 | 129,000 3.69 | 3.66 93,000 | 90,000 2.51 | 2.46 29.1 | 29.2 208 / 230 25.8 / 23.6 8.73 / 8.73 94 / 93 27.3 / 24.9 9.34 / 9.34 95 / 94 26.8 / 24.5 9.16 / 9.16 95 / 94 28.8 / 26.4 9.87 / 9.87 95 / 94 1 / 1 12 144,000 42.2 162,000 47.5 138,000 | 138,000 11.7 | 10.4 22.0 | 25.4 154,000 | 154,000 3.26 | 3.32 100,000 | 96,000 2.42 | 2.53 28.0 | 28.0 30.7 / 28.0 10.5 / 10.5 95 / 94 37.1 / 33.9 12.7 / 12.7 95 / 94 36.8 / 33.6 12.6 / 12.6 95 / 94 38.3 / 35.0 13.1 / 13.1 95 / 94 Inverter driven Rotary×2 9,000 80 9,000 R410A / 22.0 R410A / 26.0 595 3/4" 3/8" 1/4" 5/8" 53.0 / 50.0 14 72-33/64" x 46-29/64" x 39-3/8" 597 752 756 Cooling: 14~122°FDB, Heating: -13~64°FWB 7/8" 1-1/8" 1-1/8" 3/8" 1/2" 1/2" 1/4" 1/4" 1/4" 3/4" 7/8" 7/8" (Liquid,Balance)Flared,(Gas)Brazing ~1,640 164 / 131 56.0 / 53.0 57.5 / 54.5 58.0 / 55.0 19 24 28 14 168,000 49.2 189,000 55.4 160,000 | 160,000 10.8 | 10.6 20.7 | 24.9 180,000 | 176,000 3.29 | 3.22 126,000 | 118,000 2.47 | 2.70 26.4 | 27.2 39.9 / 36.5 13.5 / 13.5 94 / 93 43.9 / 40.1 14.9 / 14.9 94 / 93 42.6 / 39.0 14.4 / 14.4 94 / 93 45.7 / 41.8 15.5 / 15.5 94 / 93 Inverter driven Rotary 1+1 7,000+8,100 R410A / 18.3+18.3 72-33/64" x 95-9/32" x 39-3/8" 595 + 597 1-1/8" 5/8" 1/4" 7/8" 58.0 / 55.0 33 * NOTE: *1 If the longest tubing equivalent length exceeds 295 ft. (90m), increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes. *2 It's necessary to charge additional refrigerant of 70.5 oz (2.0 kg) per one outdoor unit. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

14
Panasonic ECOi Heat Recovery series offers the ability to heat and cool different zones
simultaneously° Offering all the features of our standard heat pump series, the 3-Way
solution can offer even higher energy savings for the building owner°
MF 2 SERIES
ECOi EX
3-WAY VRF
HEAT RECOVERY
ECOi EX
Series
*
NOTE
:
*1 If the longest tubing equivalent length exceeds 295 ft. (90m), increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes.
*2 It's necessary to charge additional refrigerant of 70.5 oz (2.0 kg) per one outdoor unit.
MODEL NAME
U-72MF2U9
U-96MF2U9
U-120MF2U9
U-144MF2U9
WU-168MF2U9
Consisted of
U-72MF2U9
U-96MF2U9
U-120MF2U9
U-144MF2U9
U-72MF2U9
+
U-96MF2U9
Appearance
Nominal Tons
6
8
10
12
14
Performance test condition
AHRI Standard 1230
Power supply
3
208/230V 60Hz
Cooling capacity
Btu/h
72,000
96,000
120,000
144,000
168,000
kW
21.1
28.1
35.2
42.2
49.2
Heating capacity
Btu/h
81,000
108,000
135,000
162,000
189,000
kW
23.7
31.6
39.6
47.5
55.4
Rating Standard
AHRI 1230
Indoor unit
Ducted
|
Non-ducted
Cooling
Capacity
Btu/h
69,000 | 69,000
92,000 | 90,000
114,000 | 114,000
138,000 | 138,000
160,000 | 160,000
EER
12.7 | 13.3
11.1 | 10.8
11.7 | 11.7
11.7 | 10.4
10.8 | 10.6
IEER
22.3 | 28.5
23.2 | 25.6
22.4 | 27.4
22.0 | 25.4
20.7 | 24.9
High heating 47°F
Capacity
Btu/h
77,000 | 77,000
103,000 | 103,000
129,000 | 129,000
154,000 | 154,000
180,000 | 176,000
COP
3.70 | 3.90
3.32 | 3.39
3.69 | 3.66
3.26 | 3.32
3.29 | 3.22
Low heating 17°F
Capacity
Btu/h
56,000 | 56,000
70,000 | 62,000
93,000 | 90,000
100,000 | 96,000
126,000 | 118,000
COP
2.66 | 2.56
2.44 | 2.38
2.51 | 2.46
2.42 | 2.53
2.47 | 2.70
SCHE
27.6 | 30.2
29.8 | 28.4
29.1 | 29.2
28.0 | 28.0
26.4 | 27.2
Electrical ratings
Outdoor unit only
Voltage
V
208 / 230
Ducted cooling
Running current
A
14.4 / 13.2
22.0 / 20.1
25.8 / 23.6
30.7 / 28.0
39.9 / 36.5
Power input
kW
4.89 / 4.89
7.46 / 7.46
8.73 / 8.73
10.5 / 10.5
13.5 / 13.5
Power factor
%
94 / 93
94 / 93
94 / 93
95 / 94
94 / 93
Ducted heating
Running current
A
16.4 / 15.0
24.7 / 22.5
27.3 / 24.9
37.1 / 33.9
43.9 / 40.1
Power input
kW
5.62 / 5.62
8.35 / 8.35
9.34 / 9.34
12.7 / 12.7
14.9 / 14.9
Power factor
%
95 / 94
94 / 93
95 / 94
95 / 94
94 / 93
Non-ducted
cooling
Running current
A
14.0 / 12.8
23.0 / 21.0
26.8 / 24.5
36.8 / 33.6
42.6 / 39.0
Power input
kW
4.74 / 4.74
7.78 / 7.78
9.16 / 9.16
12.6 / 12.6
14.4 / 14.4
Power factor
%
94 / 93
94 / 93
95 / 94
95 / 94
94 / 93
Non-ducted
heating
Running current
A
15.9 / 14.5
25.0 / 22.9
28.8 / 26.4
38.3 / 35.0
45.7 / 41.8
Power input
kW
5.43 / 5.43
8.47 / 8.47
9.87 / 9.87
13.1 / 13.1
15.5 / 15.5
Power factor
%
95 / 94
94 / 93
95 / 94
95 / 94
94 / 93
Starting current
A
1 / 1
Compressor type/quantity
Inverter driven Rotary×1
Inverter driven Rotary×2
Inverter driven
Rotary 1+1
Air flow rate
CFM
7,000
8,100
9,000
9,000
7,000+8,100
External static pressure
Pa (in. WC)
80
Refrigerant amount at shipment*
2
lbs
R410A / 18.3
R410A / 18.3
R410A / 22.0
R410A / 26.0
R410A / 18.3+18.3
Dimensions H x W x D
inch
72-33/64” x 46-29/64” x 39-3/8”
72-33/64” x 95-9/32”
x 39-3/8”
Net weight
lbs
595
597
752
756
595 + 597
Ambient temperature operating range
Cooling: 14~122°FDB, Heating: -13~64°FWB
Piping
Diameter
Gas
inch
3/4"
7/8"
1-1/8"
1-1/8"
1-1/8"
Liquid
inch
3/8"
3/8"
1/2"
1/2"
5/8"
Balance
inch
1/4"
1/4"
1/4"
1/4"
1/4"
Discharge
inch
5/8"
3/4"
7/8"
7/8"
7/8"
Connecting method
(Liquid,Balance)Flared,(Gas)Brazing
Max total pipe length
Ft
~
1,640
Elevation difference (OD upper/ OD lower)
Ft
164 / 131
Operation sound (Normal/Quiet mode)
dB
53.0 / 50.0
56.0 / 53.0
57.5 / 54.5
58.0 / 55.0
58.0 / 55.0
Maximum allowable indoor unit connection
14
19
24
28
33