Panasonic ACC-195674 ECOi VRF Systems Catalog - Page 32
Control Systems
View all Panasonic ACC-195674 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
CONTROL SYSTEMS SIMPLE SYSTEM CONTROL NETWORK Panasonic system control network is the heart and soul of the ECOi™ unit, enabling it to live with the living inside. With a simple two-wire loop installation, we put control in your hands, literally. No outside specialists required, it's an all-in-one solution for you, and a way to further build profits by keeping installation in-house. The logic resides in the ECOi system and the control is the gateway. CZ-RTC5 / CZ-RTC4 / CZ-RWSC3 / CZ-RWSU3U CZ-RWST2U / CZ-RWSD2U CZ-RWSK1U / CZ-RE2C2 / CZ-CAPC2U / CZ-64ESMC1U CZ-ESWC2 / CZ-256ESMC1U / CZ-CFUNC1U CZ-CSRC2 / CZ-CLNC1U / BMS-CTRL1 CZ-CSWKC1U / CZ-CSWAC1U / CZ-CSWGC1U CZ-CSWBC1U / CZ-CSWWC1U AN ALL-IN-ONE SOLUTION FOR YOU, NO OUTSIDE SPECIALISTS REQUIRED. PART NUMBER DESCRIPTION CZ-RTC5 HIGH-SPEC WIRED REMOTE CONTROLLER Touch key operation, weekly timer, energy saving functions etc. (Ref.P10-11) CZ-RTC4 WIRED REMOTE CONTROLLER - 7- day setback, mode, temp, service, etc CZ-RWSC3 REMOTE CONTROLLER RECEIVER - To be used with CZ-RWSK1U CZ-RWSU3U WIRELESS REMOTE CONTROLLER - For use with MU models CZ-RWST2U WIRELESS REMOTE CONTROLLER - For use with MT models CZ-RWSD2U WIRELESS REMOTE CONTROLLER - For use with MD models CZ-RWSK1U WIRELESS REMOTE CONTROLLER - For use with MK and MY models & for use with CZ-RWSC3 CZ-RE2C2 SIMPLE REMOTE CONTROLLER - on/off, Mode, Temp, Fan Speed, Flap, Service Function CZ-CAPC2U INTERFACE ADAPTOR - For On/Off Control, External Device CZ-64ESMC1U SYSTEM CONTROLLER - Set individual indoor unit temps for up to 4 zones, 16 indoor units max per zone CZ-ESWC2 SCHEDULE TIMER - Thermal On/Off at program times only, no set back temperature CZ-256ESMC1U INTELLIGENT CONTROLLER ( Web Enabled ) - Controls Max of 256 indoor units with CZ-CFUNC1U CZ-CFUNC1U COMMUNICATIONS ADAPTOR - Used with INTELLIGENT CONTROLLER and BMS interface CZ-CSRC2 REMOTE SENSOR CZ-CLNC1U LONWORKS INTERFACE - Maximum of 16 indoor units BMS-CTRL1 BMS INTERFACE - BACnet, LONworks, N2 or MODBUS (also requires CZ-CFUNC1U) CZ-CSWKC1U P-AIMS - Base Software Package CZ-CSWAC1U P-AIMS - Electrical Power Distribution Proportioning Software (also requires CZ-CFUNC1U) CZ-CSWGC1U P-AIMS - Layout Graphic Display Software (also requires CZ-CFUNC1U) CZ-CSWBC1U P-AIMS - BACnet Interface Software (also requires CZ-CFUNC1U) CZ-CSWWC1U P-AIMS - Web Enabling Software (also requires CZ-CFUNC1U) 32