3.2 Clock Settings Method Access level : POST : Admin CGI item name URL NTP settings /cgi-bin/time Clock settings /cgi-bin/date_tim e Parameter name time_adjust ntp_addr_dhc p ntp_addr ntp_port ntp_interval display date_year date_month date_day date_hour date_min date_sec timezone Parameter value 0 1 0 1 String Numeric value Numeric value 0 1 2013 to 2035 1 to 12 1 to 31 0 to 23 0 to 59 0 to 59 1 to 75 Description 0: Manual 1: Synchronized with the NTP server 0: OFF (manual input) 1: ON (acquired from DHCP) IP address 1 to 65535 1 to 24 (hours) 0: off 1: on Year Month Day Hour Minutes Seconds 1 to 75 Usage example) NTP settings http://192.168.0.10/cgi-bin/time?time_adjust=1&ntp_addr_dhcp=0&ntp_addr=192.168.0.1&ntp_port=123 &ntp_interval=12 Usage example) Clock settings http://192.168.0.10/cgi-bin/date_time?display=0&date_year=2015&date_month=1&date_day=1&date_ho ur=0&date_min=0&date_sec=0 3.3. Video over IP Settings Method Access level : POST : Admin CGI item name URL JPEG settings /cgi-bin/set_jpeg Parameter name jpeg_quality Parameter value 0 to 9 jpeg_quality_ ch2 jpeg_quality_ ch3 0 to 9 0 to 9 Description 0 to 4: High image quality 5 to 9: Low image quality 0 to 4: High image quality 5 to 9: Low image quality 0 to 4: High image quality 5 to 9: Low image quality Integrated Camera Interface Specifications / Supplement for Web Control 26