Panasonic CS-E9RKUAW E12RKUA Service Manual - Page 57

Setting Temperature and Fan Speed Shift

Page 57 highlights

 ECONAVI Start condition.  Press ECONAVI button.  ECONAVI Stop condition.  Press ECONAVI button again.  OFF Timer activates.  Press OFF/ON button to turn off the air conditioner.  Press AUTO OFF/ON button to turn off the air conditioner.  Press POWERFUL/QUIET button.  AUTO COMFORT Start condition.  Press AUTO COMFORT button.  AUTO COMFORT Stop condition.  Press AUTO COMFORT button again.  OFF Timer activates.  Press OFF/ON button to turn off the air conditioner.  Press AUTO OFF/ON button to turn off the air conditioner.  Press POWERFUL/QUIET button.  ECONAVI and AUTO COMFORT operation could ON when any of the following conditions is fulfilled:  During forced cooling or forced heating operation.  Power Failure  ECONAVI and AUTO COMFORT operation will be resuming after recovered from power failure.  Timer Operation  When unit is turn on by ON Timer and ECONAVI and AUTO COMFORT operation is ON during previous operation before OFF, ECONAVI and AUTO COMFORT operation will not be ON automatically.  When unit is turn on by ON Timer and ECONAVI and AUTO COMFORT operation is OFF during previous operation before OFF, ECONAVI and AUTO COMFORT operation will not be ON automatically.  Other Information  ECONAVI and AUTO COMFORT, Powerful, Quiet and Mild Dry Cooling cannot be operated at the same time.  ECONAVI and AUTO COMFORT sensor initialized time is 70 seconds from power supplied to ECONAVI and AUTO COMFORT sensor, or 70 seconds from the operation start.  Setting Temperature and Fan Speed Shift  Mono Sensor ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy. Mode COOL/DRY HEAT Human Low activity Normal activity High activity Set temperature +2°F / +1°C -4°F / -2°C Absent +4°F / +2°C -4°F / -2°C AUTO COMFORT ; Detecting human presence and activity, the unit controls room temperature to keep human comfortable consistently. Mode COOL/DRY HEAT Human Low activity Normal activity Set temperature +2°F / +1°C +0.5°F / +0.3°C Set Fan Speed +1 tap* High activity -2°F / -1°C -4°F / -2°C +1 tap Absent +4°F / +2°C -4°F / -2°C * During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached. ** During human absence, maximum fan speed for COOL/DRY mode is medium fan. 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143

57
ECONAVI Start condition.
Press ECONAVI button.
ECONAVI Stop condition.
Press ECONAVI button again.
OFF Timer activates.
Press OFF/ON button to turn off the air conditioner.
Press AUTO OFF/ON button to turn off the air conditioner.
Press POWERFUL/QUIET button.
AUTO COMFORT Start condition.
Press AUTO COMFORT button.
AUTO COMFORT Stop condition.
Press AUTO COMFORT button again.
OFF Timer activates.
Press OFF/ON button to turn off the air conditioner.
Press AUTO OFF/ON button to turn off the air conditioner.
Press POWERFUL/QUIET button.
ECONAVI and AUTO COMFORT operation could ON when any of the following conditions is fulfilled:
During forced cooling or forced heating operation.
Power Failure
ECONAVI and AUTO COMFORT operation will be resuming after recovered from power failure.
Timer Operation
When unit is turn on by ON Timer and ECONAVI and AUTO COMFORT operation is ON during previous
operation before OFF, ECONAVI and AUTO COMFORT operation will not be ON automatically.
When unit is turn on by ON Timer and ECONAVI and AUTO COMFORT operation is OFF during
previous operation before OFF, ECONAVI and AUTO COMFORT operation will not be ON automatically.
Other Information
ECONAVI and AUTO COMFORT, Powerful, Quiet and Mild Dry Cooling cannot be operated at the same
time.
ECONAVI and AUTO COMFORT sensor initialized time is 70 seconds from power supplied to ECONAVI
and AUTO COMFORT sensor, or 70 seconds from the operation start.
Setting Temperature and Fan Speed Shift
Mono Sensor
Low activity
Normal activity
Human
Mode
Set
temperature
High activity
Absent
ECONAVI
; Detecting human presence and activity, the unit controls room temperature to save energy.
Low activity
Normal activity
Human
Mode
Set
temperature
High activity
Absent
Set
Fan Speed
AUTO COMFORT
; Detecting human presence and activity, the unit controls room temperature to keep human
comfortable consistently.
HEAT
COOL/DRY
HEAT
COOL/DRY
*
During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached.
** During human absence, maximum fan speed for COOL/DRY mode is medium fan.
+1 tap
+1 tap*
+2°F / +1°C
+2°F / +1°C
+0.5°F / +0.3°C
-2°F / -1°C
-4°F / -2°C
+4°F /
+2°C
-4°F /
-2°C
-4°F / -2°C
+4°F /
+2°C
-4°F /
-2°C