Panasonic MCV5261-MUL MCV5261 User Guide - Page 32

REPLACING BRUSHES, Brush, Push Off

Page 32 highlights

Replacing Brushes Card Carte Tarjeta ➢ When the bristles on the agitator are worn so that they do not touch a card held across the lower plate, the brushes should be replaced. ➢ Remove lower plate and agitator. E-Clip Bride en E Sujetador de E Agitator Shaft Arbre d'entraînement Eje del agitador Right End Cap Bouchon droit Tapa de extremo derecho ➢ Remove the E-clip from agitator shaft and end cap. ➢ Do not bend agitator shaft or lose Eclip. ➢ Pull agitator shaft out of agitator body. Belt Pulley Poulie de la courroie Polea para correa Agitator Holder Support de l'agitateur Soporte del agitador Push Off Pousser Empuje hacia Brush fuera Brosse Cepillo ➢ Pull, or pry out, agitator holder and agitator pulley. ➢ Push each brush out of agitator body as shown. ➢ Install new brushes by reversing procedure. ➢ Reinstall agitator holder and agitator pulley completely. ➢ Reinstall the agitator shaft, end cap and E-clip. ➢ See exploded view for correct assembly of parts. ➢ Position belt over agitator pulley on the agitator. ➢ Reinstall agitator and lower plate. - 32 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

- 32 -
Agitator Holder
Soporte del agitador
Support de l'agitateur
Belt Pulley
Poulie de
la courroie
Polea para
correa
Brush
Brosse
Cepillo
Push Off
Pousser
Empuje hacia
fuera
Replacing Brushes
Card
Carte
Tarjeta
E-Clip
Bride en E
Sujetador
de E
Agitator Shaft
Eje del agitador
Arbre d
entra
î
nement
Right End Cap
Bouchon droit
Tapa de extremo
derecho
When the bristles on the agitator are
worn so that they do not touch a card
held across the lower plate, the
brushes should be replaced.
Remove lower plate and agitator.
Remove the E-clip from agitator shaft
and end cap.
Do not bend agitator shaft or lose E-
clip.
Pull agitator shaft out of agitator
body.
Pull, or pry out, agitator holder and
agitator pulley.
Push each brush out of agitator body
as shown.
Install new brushes by reversing
procedure.
Reinstall agitator holder and agitator
pulley completely.
Reinstall the agitator shaft, end cap
and E-clip.
See exploded view for correct
assembly of parts.
Position belt over agitator pulley on
the agitator.
Reinstall agitator and lower plate.