iCHLOR® SALT CHLORINE GENERATOR (SCG) TEST KIT (P/N 523449) INSTALLATION INSTRUCTIONS What you will need to perform the iCHLOR SCG test: • Pentair iCHLOR SCG Power Supply (PC100) • Cell Stand • Stand O-Ring • Flow Switch Activator (PVC Pipe - 1"diameter x 1.78" length) • 1 gallon of water [not included in kit] • Pool Salt (99.8% or higher pure NaCl) [not included in kit] Water Inlet Port iCHLOR SCG 1. Make 3500 ppm salinity test solution. Use calibrated salt meter to confirm salinity. It is recommended to use 12-13 grams of salt to one gallon of water. The TDS in tap water will affect the amount of salt needed. The water temperature should be around 77°F (room temperature). 2. Place the O-Ring in the Stand. 3. Remove the iCHLOR Crosshair Insert if present in the Water Inlet Port of the iCHLOR SCG. Insert PVC pipe into the Water Inlet Port of the iCHLOR SCG to activate flow switch, then thread the Water Inlet Port onto the Stand. Flow Switch Activator (PVC Pipe) Stand Remove Croshairs Insert (if present) 4. To apply power to the iCHLOR SCG, connect power cable to the iCHLOR Power Supply, then plug the iCHLOR SCG Power Supply into a 120VAC wall outlet. 1 iCHLOR Salt Chlorine Generator Test Kit Installation Instructions

  • 1
  • 2
  • 3
  • 4

iCHLOR Salt Chlorine Generator Test Kit Installation Instructions
What you will need to perform the iCHLOR SCG test:
Pentair iCHLOR SCG Power Supply (PC100)
Cell
Stand
Stand O-Ring
Flow Switch Activator (PVC Pipe - 1”diameter x 1.78” length)
1 gallon of water
[not included in kit]
Pool Salt (99.8% or higher pure NaCl) [not included in kit]
1.
Make 3500 ppm salinity test solution. Use calibrated salt meter to confirm salinity.
It is recommended to use 12-13 grams of salt to one gallon of water. The TDS in
tap water will affect the amount of salt needed.
The water temperature should be
around 77°F (room temperature).
2.
Place the O-Ring in the Stand.
3. Remove the iCHLOR Crosshair Insert if present in the Water Inlet Port of the iCHLOR
SCG. Insert PVC pipe into the Water Inlet Port of the iCHLOR SCG to activate flow
switch, then thread the Water Inlet Port onto the Stand.
4. To apply power to the iCHLOR SCG, connect power cable to the iCHLOR Power
Supply, then plug the iCHLOR SCG Power Supply into a 120VAC wall outlet.
iCHLOR
®
SALT CHLORINE GENERATOR (SCG)
TEST KIT (P/N 523449)
INSTALLATION INSTRUCTIONS
1
Water Inlet Port
iCHLOR
SCG
Stand
Flow Switch
Activator
(PVC Pipe)
Remove
Croshairs
Insert (if present)