Pentair iChlor Salt Chlorine Generator Test Kit Installation Instructions - En - Page 2
The SALT - lights
View all Pentair iChlor Salt Chlorine Generator manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
5. Set the Chlorine output to "0 %" by pressing the LESS button when Output is flashing on the digital display. The digital display will stop flashing after a few seconds after the desired setting is programmed. 6. Pour test solution into water outlet port of the iCHLOR® SCG and fill until water level is above the cell blades. 7. Verify that the FLOW LED is GREEN on the iCHLOR SCG control panel, indicating flow switch is activated and unit is operating. • If FLOW LED is red, the flow switch has not been activated. Check that Step 3 has been completed, and that the Stand is fully threaded into the iCHLOR SCG. • If FLOW LED remains red, then Flow Switch has a malfunction and needs to be replaced. • If CELL LED has a "short flash RED", the unit has deteced a malfunction on the temperature sensor and the Flow Switch needs to be replaced. 8. The SALT LED will flicker between RED to GREEN for about 2 minutes as it takes readings. After 2 minutes the SALT level LED will display. If the SALT LED is flashing GREEN after 2 minutes, then the unit has detected a salinity level above 4500 ppm. Verify salinity of test water. SALT LED STATUS LED LESS/MORE BUTTONS 9. Press and hold the MORE button for 3 seconds to enable "Diagnostic Mode". The SALT and STATUS LEDs will light up in sequence when the diagnostic mode is activated. 2 iCHLOR Salt Chlorine Generator Test Kit Installation Instructions