Problem Cause Remedy AE lock function does not operate AE lock is not available when set to B (Green), p (Bulb) or M (Flash X-sync speed) mode Use AE lock with any setting other than B (Green), p (Bulb) or M (Flash X-sync speed) mode. The flash does not discharge Only C (Auto discharge) and D (Auto flash+Redeye reduct) are available for the The Capture mode is set to B (Green) mode Flash Mode when the Capture mode is B. The flash will not discharge when the subject is bright in these modes. In the Capture modes other than B, only the flash mode that discharges every time the flash recharges is available. Try different Capture modes. The USB connection with a computer does not work The Transfer Mode is set to [PictBridge] Set [USB Connection] in the [R Set-up] menu to [PC]. properly* The USB connection with a printer does not work properly The Transfer Mode is set to [PC] Set [USB Connection] in the [R Set-up] menu to [PictBridge]. (p.208) The Shake Reduction function Turn on the Shake Reduction switch. is off Shake Reduction does not work The Shake Reduction function is not set properly Shutter speed is too low for the Shake Reduction function to be effective when panning or shooting night scenes, etc. If a lens for which focal length information cannot be acquired is used, set the [Focal Length] on the [Input Focal Length] menu. (p.67) Turn off the Shake Reduction function and use a tripod. The subject is too Move away from the subject, or turn off the close Shake Reduction function and use a tripod. In rare cases, the camera may not operate correctly due to static electricity. This can be remedied by taking the battery out and putting it back in again. When the mirror remains in the up position, take the battery out and put it back in again. Then, turn the power on. The mirror will retract. After the procedure is done, if the camera operates correctly, it does not require any repairs. * Refer to p.11 of the "PENTAX PHOTO Browser 3/PENTAX PHOTO Laboratory 3 Operating Manual" for details on connecting the camera to a PC. Appendix 265 12