Pioneer IS-21T Service Manual - Page 24
SINGLE OPERATION METHOD, Jigs and Measuring instruments, Single operation method and frequnency
View all Pioneer IS-21T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
XC-IS21T 7.1.2 SINGLE OPERATION METHOD Jigs and Measuring instruments VA Low-frequency DC power- oscillator supplay Single operation method and frequnency oscilator inputlevel. 1. Connect part A of the AF ASSY [W420(+8V),W421 (+15V), W422 (+5.6V), W423(GND) and DC power-supplay. (Refer to Fig. 7-1.) Connect point A AF ASSY, W420 (+8v) AF ASSY, W421 (+15v) AF ASSY, W422 (+5.6v) AF ASSY, W423 (GND) DC power-supplay Voltage (V) Remarks +8V +15V +5.6V GND 2. Connect part B of the U-COM ASSY [ CN105 pin8 (AC), AF ASSY[W423 (GND)] and frequency oscillator. (Refer to Fig. 7-1 and 7-2.) Connect point B U-COM ASSY, CN105 pin8 (AC) AF ASSY, W423 (GND) frequency 50 or 60 Hz Low-frequency oscillator level Gnd Approx.2.0 Vrms osc GND Note: Set up the low-frequncy oscillator level with in the limits of product moves. Remarks Note. 58