ProForm 10.8x Bike English Manual - Page 18
Maintenance And Troubleshooting
View all ProForm 10.8x Bike manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
MAINTENANCE AND TROUBLESHOOTING Inspect and properly tighten all parts of the exercise bike regularly. Replace any worn parts immediately. To clean the exercise bike, use a damp cloth and a small amount of liquid dish soap. IMPORTANT: To avoid damaging the console, keep liquids away from the console and keep the console out of direct sunlight. CONSOLE TROUBLESHOOTING With the left shield removed, locate the Reed Switch (43). Turn the Crank (31) until the Magnet (38) is aligned with the Reed Switch. Next, loosen, but do not remove, the indicated M4 x 16mm Screw (57). Slide the Reed Switch slightly closer to or away from the Magnet, and then retighten the Screw. Turn the Crank for a moment. Repeat until the console displays correct feedback. When the Reed Switch is correctly adjusted, reattach the left shield and the left pedal. If the console display becomes dim, replace all the batteries at the same time; most console problems are the result of low batteries. To replace the batteries, see assembly step 7 on page 8. If the handgrip pulse sensor does not function properly, see step 5 on page 14. HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, you must first remove the Left Shield (9). Using an adjustable wrench, turn the Left Pedal (24) clockwise and remove it. Next, remove the seven M4 x 16mm Screws (57) and the M4 x 25mm Screw (45). Then, carefully remove the Left Shield. 31 43 57 38 9 57 57 24 57 57 45 18