Pyle PDMM01 PDMM01 Manual 1 - Page 5

Operation

Page 5 highlights

Operation 1. Power Press the ON/OFF button to turn power on or off. The meter will perform a short self-test when turned on. The meter defaults to the setting used during the last operation. 2. Zero Adiust and Offset Before use and without fittings attached to the meter, press the HOLD button for more than 2 seconds to zero the meter. The meter will reset and display "000" from right to left. 0 .000 will be display. If it is desired to offset the meter and display, press the DIF button while taking a measurement subsequent reading will be the difference between the current measurement and the measurement that was on the display when the DIF button was pressed. 3. Data Hold Press the HOLD button momentarily to freeze the displayed reading the HOLD icon will appear on the upper left-hand side of the display. press the HOLD button again to return to normal operation. 4 Record The MAX/MIN mode allows the user to view only the highest (MAX), lowest (MIN) or anerage (AVG) readings with relative time stamp. 1. Press the REe button once and REe appears on the display (All other Functions are locked out except for Power & Backlight) . The relative time clock also appears in the secondary display and starts counting . 2 . Press the REe button again and MAX appears on the display. The Display is now showing the maximum pressure and relative time it was recorded . 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

Operation
1.
Power
Press
the
ON/OFF
button to turn
power
on
or
off
.
The
meter will perform
a short self-test when turned on.
The
meter defaults to the setting used during
the last operation.
2.
Zero
Adiust
and
Offset
Before
use
and without fittings attached to the meter, press the
HOLD
button
for more than 2 seconds to zero the meter.
The
meter will reset and display
"000"
from right to left. 0.
000
will be display.
If
it
is
desired to offset the meter and display, press the
DIF
button while
taking a measurement subsequent reading will be the difference between the
current measurement and the measurement that was on the display when the
DIF
button was pressed.
3.
Data
Hold
Press
the
HOLD
button momentarily to freeze the displayed reading the
HOLD
icon will
appear
on the upper left-hand side
of
the display. press the
HOLD
button
again
to return to normal operation.
4 Record
The
MAX/MIN
mode allows the user to view only the highest
(MAX),
lowest
(MIN)
or
anerage
(AVG)
readings with relative time stamp.
1 .
Press
the
REe
button once and
REe
appears on the display (All other
Functions are locked out except for Power
&
Backlight).
The
relative time
clock also appears
in
the secondary display and starts counting.
2.
Press
the
REe
button
again
and
MAX
appears on the display.
The
Display
is
now
showing the maximum pressure and relative time it was
recorded.
3