RCA RMW1749-SS English Manual - Page 27
Charcoal Filter, Oven Light
![]() |
View all RCA RMW1749-SS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Charcoal Filter Charcoal filter is used for nonvented, recirculated installation. The filter should be changed every 6 to 12 months depending on use. Disconnect power to the oven at the circuit breaker panel or by unplugging. Remove the louver mounting screw from the top center of the louver and push down carefully on the tab at each end of the louver to disengage it. (See illustration.) Pull the louver away from the unit. Change the charcoal filter. Carefully push the louver back into place and replace the screw remove in step 2. Oven Light Remove the louver per instructions 1~3 above and charcoal filter, if used. Open light cover located behind filter mounting by carefully pulling up on the front edge. DO NOT USE A BULB LARGER THAN 30 WATTS. Replace the oven light cover by carefully pushing into place. Replace the charcoal filter, if used. Push the louver back into place and replace the louver mounting screw. 27
![](/manual_guide/products/rca-rmw1749ss-english-manual-3407939/27.png)