Rane CP64S CP64S Data Sheet - Page 2

CP64S - commercial processor

Page 2 highlights

CP64S COMMERCIAL PROCESSOR Features and Specifications Parameter MIC/LINE PAGING INPUTS ..........Input Type ..........RFI Filter ..........Gain range ..........Frequency Response ..........Input Referred Noise ..........CMR ..........THD+N ..........Phantom Power ..........Mic Input impedance ..........Line Pad ..........Line Input impedance ..........Signal Detector Range ..........Signal Detector Attack ..........Signal Detector Release ..........Overload Indicator ..........Front Panel Zone Assign ..........Remote Zone Assign ..........Pre/Post Paging assign ..........Page Priority Assign ..........Paging Zone Level Adjust ..........Page Remote Selector PROGRAM INPUTS ..........Input Type ..........Input Level adjust ..........Frequency Response ..........Input impedance .....Priority Program Input Input Detector Range Release Time Range Attack Time Assign EXPAND OUTPUTS ..........Number of Expand Outputs ..........Expand Selector ..........Output Type ..........Gain: Zone Page/Program ..........Frequency Response Specification Limit Units Conditions/Comments Two mono All controls duplicated for both inputs Euroblock Balanced; Instrumentation amplifier Yes +30 to +60 2 dB Continuously adjustable 30 Hz to 40 kHz +0/-3 dB Maximum gain -125 1 dBu Gain: 60 dB, Rs: 150 Ω, BW: 20 kHz 40 min dB 20 to 20 kHz .05 .01 % Gain: 30 dB, +4 dBu out, 1 kHz, BW: 80 kHz +15 4% VDC Internal switch 500 1% Ω Each leg to ground 30 1 dB 14.5k 1% Ω Each leg to ground. Defeats phantom power off to +4 typ dBu Continuously adjustable .5 typ msec Fixed 3 typ sec Fixed +16 1 dBu 4 dB before clipping. Remote, Z1, Z2, Both Z1 = Zone 1; Z2 = Zone 2 Off, Z1, Z2, Both Internal pull-up; Active low; Switch closure to ground or 5 volt TTL logic. Summed with program Pre VCA or Post VCA via Internal switch P1 (Page 1) NO (none) P2 (Page 2) 1 dBu Priority pager overrides non-priority pager only in assigned zones; Selecting NONE allows the two pagers to mix. off to 0 dB Independent for each Zone 11 = Off 10 = Z1 (Zone 1) 01 = Z2 (Zone 2) 00 = Both 1 dBu Internal pull-up. Active low; Switch closure to Ground or 5 volt TTL logic. Four stereo All controls duplicated for all four inputs RCA Unbalanced off to 0 dB 10 Hz to 50 kHz +0/-3 dB 10 k 20% Ω off to -35 5 to 20 50 OFF, Z1, Z2 or Both Two Zone Program only Page only Balanced 12 6 10 Hz to 50 kHz typ dBu Internal trim, factory set to -50 dBu typ sec Internal trim, factory set to 12 seconds typ msec For a 20 dB step; Fixed. 1 dB 1 dB +0/-3 dB All controls duplicated for both zones Z1 & Z2, both mono Note: If a Page signal is summed Post-VCA, it is not present on the Expand Zone output. It is available for the Expand Page output. Cross-coupled; Euroblock connector Data Sheet-2 continued...

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Data Sheet-2
CP64S
COMMERCIAL PROCESSOR
Parameter
Specification
Limit
Units
Conditions/Comments
MIC/LINE PAGING INPUTS
Two mono
All controls duplicated for both inputs
..........
Input Type
Euroblock
Balanced; Instrumentation amplifier
..........
RFI Filter
Yes
..........
Gain range
+30 to +60
2
dB
Continuously adjustable
..........
Frequency Response
30 Hz to 40 kHz
+0/-3
dB
Maximum gain
..........
Input Referred Noise
-125
1
dBu
Gain: 60 dB, Rs: 150 Ω, BW: 20 kHz
..........
CMR
40
min
dB
20 to 20 kHz
..........
THD+N
.05
.01
%
Gain: 30 dB, +4 dBu out, 1 kHz, BW: 80 kHz
..........
Phantom Power
+15
4%
VDC
Internal switch
..........
Mic Input impedance
500
1%
Ω
Each leg to ground
..........
Line Pad
30
1
dB
..........
Line Input impedance
14.5k
1%
Ω
Each leg to ground. Defeats phantom power
..........
Signal Detector Range
off to +4
typ
dBu
Continuously adjustable
..........
Signal Detector Attack
.5
typ
msec
Fixed
..........
Signal Detector Release
3
typ
sec
Fixed
..........
Overload Indicator
+16
1
dBu
4 dB before clipping.
..........
Front Panel Zone Assign
Remote, Z1, Z2, Both
Z1 = Zone 1; Z2 = Zone 2
..........
Remote Zone Assign
Off, Z1, Z2, Both
Internal pull-up; Active low;
Switch closure to ground or 5 volt TTL logic.
..........
Pre/Post Paging assign
Summed with program Pre VCA or Post VCA via Internal switch
..........
Page Priority Assign
P1 (Page 1)
NO (none)
P2 (Page 2)
1
dBu
Priority pager overrides non-priority pager only
in assigned zones; Selecting NONE allows the
two pagers to mix.
..........
Paging Zone Level Adjust
off to 0
dB
Independent for each Zone
..........
Page Remote Selector
11 = Off
10 = Z1 (Zone 1)
01 = Z2 (Zone 2)
00 = Both
1
dBu
Internal pull-up. Active low;
Switch closure to Ground or 5 volt TTL logic.
PROGRAM INPUTS
Four stereo
All controls duplicated for all four inputs
..........
Input Type
RCA
Unbalanced
..........
Input Level adjust
off to 0
dB
..........
Frequency Response
10 Hz to 50 kHz
+0/-3
dB
..........
Input impedance
10 k
20%
Ω
.....
Priority Program Input
...............
Input Detector Range
off to -35
typ
dBu
Internal trim, factory set to -50 dBu
...............
Release Time Range
5 to 20
typ
sec
Internal trim, factory set to 12 seconds
...............
Attack Time
50
typ
msec
For a 20 dB step; Fixed.
...............
Assign
OFF, Z1, Z2 or Both
EXPAND OUTPUTS
All controls duplicated for both zones
..........
Number of Expand Outputs
Two
Z1 & Z2, both mono
..........
Expand Selector
Zone
Program only
Page only
Note: If a Page signal is summed Post-VCA, it
is not present on the Expand Zone output. It is
available for the Expand Page output.
..........
Output Type
Balanced
Cross-coupled; Euroblock connector
..........
Gain: Zone
12
1
dB
....................
Page/Program
6
1
dB
..........
Frequency Response
10 Hz to 50 kHz
+0/-3
dB
Features and Specifications
continued...