Rane CP64S CP64S Data Sheet - Page 5

Remote Controls, Example System: Retail Store

Page 5 highlights

CP64S COMMERCIAL PROCESSOR L2 L3 L1 P PROGRAM SELECT 46 2 8 0 10 LEVEL ZR1 Z1 Z2 OFF BOTH PAGE 1 ASSIGN Z1 Z2 OFF BOTH PAGE 2 ASSIGN PR2 Example System: Retail Store Remote Controls Two optional wired remote control units are available. The PR2 allows remote control of Page 1 and Page 2 Zone Assign selection. The ZR1 allows remote control of Zone Level and Zone Program selection. One PR2 and two ZR1 remotes may be used with each CP64S. The PR2 and ZR1 may be installed in standard electrical boxes (minimum depth 2.25"). The remotes connect to the CP64S through Euroblock connectors. The PR2 is a 5-wire remote with 2 bits to select Page 1 Assign, one wire for shield/gnd and 2 bits for Page 2 Assign. Selector logic is active low BCD with pull-up provided in the CP64S. Control may be a simple switch closure to ground or 5 volt TTL. Page 1 and Page 2 bits may be paralleled so that one switch controls both Page Assigns. Remote control is initiated by setting the front panel Paging Zone Assign selector to RMT. The ZR1 is a 5-wire remote with 2 bits for Zone Program selection (active low Gray Code), a common shield/ground and two wires for ratiometric DC control of Zone Level. Zone 1 and Zone 2 ZR1 remote ports may be paralleled so that a single remote controls both Zones. Selector logic is active low Gray Code with pull-up provided in the CP64S. Control may be a simple switch closure to ground or 5 volt TTL. Remote control for each zone is initiated by engaging the RMT switch (located on the front panel) for that Zone. For installations that require a volume remote but don't need the program selection of the ZR1, Rane makes the model VR1 Volume Remote. CP64S COMMERCIAL AUDIO 100-240 V EQUIPMENT 24TJ 50/60 Hz 12 WATTS R Z2 PGM Z2 LEVEL REMOTES WIRING MIN MAX Vr Vc OUTPUTS Z2 EXPAND Z2 MONO ALL AUDIO AND REMOTES ARE CLASS 2 WIRING ZONE 2 ZONE 1 EXPAND OUT EXPAND OUT ZONE PAGE ZONE PAGE RANE CORP. MADE IN U.S.A. ACN 001 345 482 Z1 PGM D1 D0 Z1 LEVEL Vr Vc 2 PGM 1 PGM Z1 EXPAND Z1 RIGHT Z1 LEFT +- +- +- PROGRAM INPUTS LIMITER PRIORITY ZONE 1 ZONE 2 ASSIGN ZONE L L +8 +8 off 1 2 -20 +20 -20 +20 R R 1&2 PRIORITY 3 2 1 ZONE 2 ZONE 1 Z2 Z1R Z1L EX1 EX2 PRIORITY 2 REMOTE PAGE REMOTE 1 INPUT 1 ZONE ASSIGN WIRING Z1 Z2 PAGING INPUTS PAGE 2 TRIM PAGE 1 TRIM PAGE 2 PAGE 1 DETECT THRESHOLD +30 +60 OL +30 +60 REMOTE 2 INPUT 2 Z2 Z1 +- MIC LINE MIC LINE IN1 IN2 PRIORITY 1 MA 4 MULTICHANNEL AMPLIFIER 1 3 Limit 6 Comp 12 Exp 24 dB Headroom 2 Fault Load Ready 3 Limit 6 Comp 12 Exp 24 dB Headroom 3 Fault Load Ready 3 Limit 6 Comp 12 Exp 24 dB Headroom 4 Fault Load Ready 3 Limit 6 Comp 12 Exp 24 dB Headroom Fault Load Ready ON DISTRIBUTED OUTPUTS REQUIRE MT 4 TRANSFORMER ACCESSORY CD PLAYER PRE-RECORDED ADVERTISEMENT OR BREAK BELL MUSIC SERVICE DVR 62 1:58 TELEPHONE PAGE OUT TELEPHONE HOLD MUSIC MA 4 DIGITAL AMPLIFIER ZR 1 L2 L3 L1 P PROGRAM SELECT 46 2 8 0 10 LEVEL PROGRAM SELECT LEVEL ZONE 2 DISTRIBUTED RETAIL / SHOP FLOOR ZR 1 L2 L3 L1 P PROGRAM SELECT 46 2 8 0 10 LEVEL PROGRAM SELECT LEVEL STEREO ZONE 1 MEETING / DEMO ROOM DISTRIBUTED EXPAND 1 OFFICE PAGE Data Sheet-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Data Sheet-5
CP64S
COMMERCIAL PROCESSOR
Remote Controls
Two optional wired remote control units are available. °e PR2
allows remote control of Page 1 and Page 2 Zone Assign selec-
tion. °e ZR1 allows remote control of Zone Level and Zone
Program selection. One PR2 and two ZR1 remotes may be
used with each CP64S. °e PR2 and ZR1 may be installed in
standard electrical boxes (minimum depth 2.25"). °e remotes
connect to the CP64S through Euroblock connectors.
°e PR2 is a 5-wire remote with 2 bits to select Page 1 As-
sign, one wire for shield/gnd and 2 bits for Page 2 Assign. Selec-
tor logic is active low BCD with pull-up provided in the CP64S.
Control may be a simple switch closure to ground or 5 volt TTL.
Page 1 and Page 2 bits may be paralleled so that one switch con-
trols both Page Assigns. Remote control is initiated by setting the
front panel Paging Zone Assign selector to RMT.
°e ZR1 is a 5-wire remote with 2 bits for Zone Program
selection (active low Gray Code), a common shield/ground and
two wires for ratiometric DC control of Zone Level. Zone 1 and
Zone 2 ZR1 remote ports may be paralleled so that a single re-
mote controls both Zones. Selector logic is active low Gray Code
with pull-up provided in the CP64S. Control may be a simple
switch closure to ground or 5 volt TTL. Remote control for each
zone is initiated by engaging the RMT switch (located on the
front panel) for that Zone.
For installations that require a volume remote but don't need
the program selection of the ZR1, Rane makes the model VR1
Volume Remote.
Example System: Retail Store
PROGRAM SELECT
LEVEL
8
2
10
0
4
6
L1
L3
L2
P
PAGE 2 ASSIGN
PAGE 1 ASSIGN
BOTH
OFF
BOTH
Z1
OFF
Z2
Z1 Z2
ZR1
PR2
SELECT
LEVEL
PROGRAM
ZR 1
PROGRAM SELECT
LEVEL
8
2
10
0
4
6
L1
L3
L2
P
TELEPHONE HOLD MUSIC
TELEPHONE
PAGE OUT
DISTRIBUTED
MA 4
MULTICHANNEL
AMPLIFIER
DISTRIBUTED OUTPUTS REQUIRE
MT 4 TRANSFORMER ACCESSORY
SELECT
LEVEL
PROGRAM
CD
PLAYER
PRE-RECORDED
ADVERTISEMENT
OR BREAK BELL
DISTRIBUTED
STEREO
DVR
62
1:58
MUSIC
SERVICE
ZR 1
ZONE 1
EX2
EX1
IN1
IN2
Z1L
Z1R
Z2
ZONE 1
EXPAND 1
ZONE 2
ZONE 2
PROGRAM SELECT
LEVEL
8
2
10
0
4
6
L1
L3
L2
P
OFFICE PAGE
RETAIL / SHOP FLOOR
MEETING / DEMO ROOM
1
2
3
4
MA 4
PRIORITY 1
PRIORITY 2
PRIORITY
ASSIGN
ZONE
ZONE
1
PAGE
+30
+60
1&2
PRIORITY
3
2
1
RANE CORP. MADE IN U.S.A.
OL
Z2
Z1
Z1
Z2
+
+
+
+
D1
D0
Vr
Vc
Vr
Vc
1
2
DETECT THRESHOLD
REMOTE PAGE
ZONE ASSIGN WIRING
PAGE 2
PAGE 1
LIMITER
WIRING
ZONE 1
ZONE 2
PAGE
1
TRIM
PAGE
2
TRIM
CP64S
+8
+8
PAGING INPUTS
R
L
R
L
+30
+60
MIC
LINE
–20
+20
–20
+20
REMOTES
OUTPUTS
MIN
MAX
PROGRAM INPUTS
ZONE
2
EXPAND OUT
ZONE
1
EXPAND OUT
ZONE
2
REMOTE
2
INPUT
2
Z1
RIGHT
Z1
EXPAND
Z1
LEFT
Z1
PGM
Z1
LEVEL
ACN 001 345 482
MIC
LINE
100-240 V
50/60 Hz 12 WATTS
COMMERCIAL AUDIO
EQUIPMENT 24TJ
R
PGM
PGM
PAGE
off
ALL AUDIO AND
REMOTES ARE
CLASS 2 WIRING