RedMax SRTZ2460 Owners Manual - Page 17
Troubleshooting guide
View all RedMax SRTZ2460 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
LRTZ2460/SRTZ2460 12. Troubleshooting guide Case 1. Starting failure CHECK fuel tank fuel filter carburetor adjustment screw sparking (no spark) spark plug PROBABLE CAUSES ➞ incorrect fuel ➞ fuel filter is clogged ➞ out of normal range ➞ spark plug is fouled/wet ➞ plug gap is incorrect ➞ disconnected ACTION ➞ drain it and with correct fuel ➞ clean ➞ adjust to normal range ➞ clean/dry ➞ correct (GAP: 0.6 - 0.7 mm) ➞ retighten Case 2. Engine starts but does not keep running/Hard re-starting. CHECK PROBABLE CAUSES fuel tank ➞ incorrect fuel or staled fuel ➞ carburetor adjustment screw ➞ out of normal range ➞ muffler,cylinder (exhaust port) ➞ carbon is built-up ➞ air cleaner ➞ clogged with dust ➞ cylinder fin, fan cover ➞ clogged with dust ➞ ACTION drain it and with correct fuel adjust to normal range wipe away replace clean When your unit seems to need further service, please consult with our service shop in your area. US-16